EasyManua.ls Logo

FLIR Raymarine p70s - General Cabling Guidance; Connections Overview

FLIR Raymarine p70s
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.1Generalcablingguidance
Cabletypesandlength
Itisimportanttousecablesoftheappropriatetype
andlength
Unlessotherwisestateduseonlystandardcables
ofthecorrecttype,suppliedbyRaymarine.
Ensurethatanynon-Raymarinecablesareofthe
correctqualityandgauge.Forexample,longer
powercablerunsmayrequirelargerwiregauges
tominimizevoltagedropalongtherun.
Routingcables
Cablesmustberoutedcorrectly,tomaximize
performanceandprolongcablelife.
DoNOTbendcablesexcessively.Wherever
possible,ensureaminimumbenddiameterof200
mm(8in)/minimumbendradiusof100mm(4in).
100 mm (4 in)
200 mm (8 in)
Protectallcablesfromphysicaldamageand
exposuretoheat.Usetrunkingorconduitwhere
possible.DoNOTruncablesthroughbilgesor
doorways,orclosetomovingorhotobjects.
Securecablesinplaceusingtie-wrapsorlacing
twine.Coilanyextracableandtieitoutoftheway.
Whereacablepassesthroughanexposed
bulkheadordeckhead,useasuitablewatertight
feed-through.
DoNOTruncablesneartoenginesoruorescent
lights.
Alwaysroutedatacablesasfarawayaspossible
from:
otherequipmentandcables,
highcurrentcarryingACandDCpowerlines,
antennae.
Caution:Pullingcables
DoNOTusecordsorropes,attached
tocableconnectors,topullcables
throughrestrictedapertures(e.g.asin
bulkheads),asthiscouldcausedamage
tocables.
Strainrelief
Ensureadequatestrainreliefisprovided.Protect
connectorsfromstrainandensuretheywillnotpull
outunderextremeseaconditions.
Cableshielding
Ensurethatalldatacablesareproperlyshielded
thatthecableshieldingisintact(e.g.hasn’tbeen
scrapedoffbybeingsqueezedthroughatightarea).
4.2Connectionsoverview
Usethefollowinginformationtohelpyouidentifythe
connectionsonyourproduct.
ConnectorQtyConnectsto:Suitablecables
1
1.SeaTalk
ng
backbone
2.NMEA2000
backbone
3.SeaTalk
backbone
1.SeaTalk
ng
spurcables
2.SeaTalk
ng
to
DeviceNet
adaptor
cable
(A06045)
3.SeaTalkto
SeaTalk
ng
adaptor
cable
(A06073)
ConnectingSeaTalk
ng®
cables
D12615-2
1.Rotatethelockingcollarontheunittothe
unlockedposition.
2.Ensurethecable’sconnectoriscorrectlyoriented.
3.Fullyinsertthecableconnector.
4.Rotatelockingcollarclockwise(2clicks)untilitis
inthelockedposition.
SeaTalk
ng®
productloading
Thenumberofproductsthatcanbeconnected
toaSeaTalk
ng
backbonedependsonthepower
consumptionofeachproductandthephysicaloverall
lengthofthebackbone.
SeaTalk
ng
productshaveaLoadEquivalency
Number(LEN),whichindicatestheproduct’spower
consumption.TheLENforeachproductcanbe
foundintheproduct’sT echnicalSpecication.
22
p70s/p70Rs

Table of Contents