Follow plant safety regulations, wear PPE, isolate equipment, lock out, and consult SDS.
Disassemble per manufacturer, remove seal, clean chamber and shaft thoroughly.
Inspect surfaces for pits/scratches, break sharp corners on shaft steps, threads, reliefs.
Check shaft runout, endplay, radial play, chamber squareness, and concentricity.
Check surface finish of seal housing, bore, and shaft (e.g., 1.6 µm Ra for housing).
Verify dimensions and review assembly drawings for any modifications.
Ensure equipment is earthed to prevent sparks from static electricity discharge.
Scribe marks on shaft/sleeve for seal housing alignment and setting point.
Lightly lubricate shaft/sleeve and O-rings/gaskets with provided lubricant.
Press stationary face into gland using hand pressure, nesting O-ring if applicable.
Install gland over shaft, then rotating components in sequence, handle PTFE carefully.
Set spring holder, tighten set screws, wipe seal faces clean before final assembly.
Position gland, ensure pilot engagement, tighten nuts evenly per torque recommendations.
Scribe marks on shaft/sleeve for seal housing alignment and setting point.
Lightly lubricate shaft/sleeve and O-rings/gaskets with provided lubricant.
Install rotating components, then stationary face into gland, handle PTFE carefully.
Set spring holder, tighten set screws, wipe seal faces clean before final assembly.
Position gland, ensure pilot engagement, tighten nuts evenly per torque recommendations.
Use procedure for single end suction vertical split case pumps for these designs.
Scribe marks on shaft/sleeve for seal housing alignment and setting point.
Lightly lubricate shaft/sleeve and O-rings/gaskets with silicone lubricant.
Install rotating components, set spring holder, and install stationary face into gland.
Position gland, ensure pilot engagement, tighten nuts evenly per torque recommendations.
Do not start dry; vent air, circulate clean fluid through seal chamber before startup.
If seal runs hot, check setting, dimensions, and bypass/flush lines for obstructions.
Use only Flowserve parts for repair. Stock spare seals to reduce repair time.
Decontaminate seal, include SDS, and mark order 'Repair or Replace'.