9500B
High Performance Oscilloscope Calibrator
Calibration Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Fluke Calibration 9500B and is the answer not in the manual?

Summary

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Introduction

Contact Fluke Calibration Calibration

Provides contact information for technical support and repair services.

Safety Information

Product Use

Lists user instructions and manuals for product operation.

Specifications

Details where to find safety and complete product specifications.

Routine Maintenance

General Cleaning

Instructions for cleaning the instrument's exterior and display screen.

Air Intake Filter

Procedure for accessing and maintaining the air intake filter.

Firmware Upgrade

Procedure

Step-by-step instructions for performing a firmware upgrade.

Model 9500 B Test and Selftest

Types of Tests

Describes the different types of self-tests available for the instrument.

Test Mode

How to access and select different test modes.

Interface Test

Access to Interface Tests

Steps to select the interface test menu for various component checks.

Error Reporting Subsystem

Error Detection

Classification and handling of instrument errors.

Error Messages

System Trip Errors

Lists and describes system trip error codes and their causes.

Recoverable Errors

Details types of recoverable errors and error reporting mechanisms.

Device-Dependent Errors (DDE)

Device-Dependent Errors Reported only Locally on the Front Panel Screen

Lists errors specific to local front panel display, without error numbers.

Verification

Need for Verification

Importance of verification, factory calibration, and traceability.

Equipment Requirements

Specifies the necessary standards and equipment for verification.

9500 B Mainframe Verification by Functions

DC;Square Function: DC Output

Procedure for verifying the DC output of the DC/Square function.

LF Sine Function

Procedure for verifying the LF Sine Voltage function.

Pulse Width Function

Procedure for verifying the pulse width measurement function.

9510;9530;9550;9560 Head Calibration Procedures

Levelled Sine Function: LF Gain Calibration

Calibrating the LF gain of the leveled sine function for specific heads.

Edge Function Calibration

Procedure for calibrating the edge function.

Calibration

9500 B Mainframe Calibration and Active Head Calibration

Overview of mainframe and active head calibration procedures.

Mainframe Unit Manual Calibration

Procedures for manual calibration of the mainframe unit.

The Model 9500 B Calibration Mode

Mode Selection

How to select operating modes like PROC, MANUAL, CONFIG, CALIB, TEST.

Selection of Calibration Mode

Conditions required to access the Calibration Mode menu.

Special Calibration

Selecting Special Calibration

How to navigate to the Special Calibration screen.

When to Characterize

Guidance on when characterization adjustments are necessary.

Special Cal: Adjust FREQ

Mainframe Standard Calibration (BASE CAL)

Function Selection

How to select functions for standard calibration.

Standard Calibration - Basic Sequences

Target Selection Screen - Selecting Hardware Configurations

How to select hardware configurations and target values.

The Adjustment Screen

Screen for performing adjustments near calibration targets.

Calibrating the Model 9500 B at Target Values

Steps for adjusting and calibrating output at target values.

Front Panel Base Calibration by Functions

DC;Square - DC Voltage Calibration

Guide to calibrating the DC Voltage function.

LF Sine Voltage Calibration

Guide to calibrating the LF Sine Voltage function.

Summary of Calibration Process

General Procedure

A step-by-step summary of the calibration process.

9510;9530;9550;9560 Head Calibration Procedures

Levelled Sine Function: LF Gain Calibration

Calibrating the LF gain of the leveled sine function for specific heads.

Edge Function Calibration

Procedure for calibrating the edge function.

Load Resistance Measurement Calibration

Introduction

Guide to calibrating the Load Resistance Measurement function.

Calibration Equipment Requirements

Lists required equipment for Load Resistance Measurement calibration.

Calibrating the Timing Markers (9510 only)

Summary

Summary of timing marker calibration.

Load Capacitance Function Calibration (9510 and 9530 only)

Equipment required - two calibrated capacitance standards

Lists the calibrated capacitance standards needed for calibration.

50 Ω; 1 MΩ Ratio Calibration

Exit from Head Calibration

Exit from Head Calibration

Steps to exit head calibration and save/abandon data.

Fluke Calibration 9500B Specifications