114, 115, and 117
Users Manual
10
Measuring Resistance
edy04f.eps
XWWarning
To avoid electric shock, injury, or
damage to the Meter, disconnect
circuit power and discharge all high-
voltage capacitors before testing
resistance, continuity, diodes, or
capacitance.
Testing for Continuity
edy06f.eps
Note
The continuity function works best as a fast,
convenient method to check for opens and
shorts. For maximum accuracy in making
resistance measurements, use the Meter’s
resistance (e) function.
Shop for Fluke products online at:
1.888.610.7664
www.MyFlukeStore.com

Other manuals for Fluke 114

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 114 and is the answer not in the manual?

Fluke 114 Specifications

General IconGeneral
Frequency range0.005 - 50 kHz
Continuity checkYes
DC voltage range0.0001 - 600 V
Resistance range1 - 600 Ω
Resistance resolution1 Ω
Resolution (DC voltage)0.0001 mV
Basic accuracy (DC voltage)1.0% + 3 (DC, 45 Hz to 500 Hz)
Temperature measurement range-40 - 400 °C
Battery type9V
Battery voltage9 V
Number of batteries supported1
Weight and Dimensions IconWeight and Dimensions
Depth46 mm
Width84 mm
Height167 mm
Weight550 g