EasyManua.ls Logo

Fluke 1520 - Specifications Manual

Fluke 1520
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Fluke 1520
MegOhmMeter
Technical Data
Large, backlit LCD with
analog bar graph and digital
display
Three output voltages for
insulation resistance testing:
250V, 500V, 1000V
Insulation resistance testing
up to 4000 M; switches
automatically to voltage
measurement when voltage
is greater than 30V ac or
30V dc.
AC/DC voltage measurement
up to 600V
Lo-Ohms function for testing
connections
Last reading memory display
4 C-cell batteries for up to
5,000 tests per EN61557-2,
with battery-life indicator
and auto shut-off.
Autodischarge of capacitive
voltage charges
Heavy duty test leads,
alligator clips and test
probes
Rugged, splash-proof case
with impact-absorbing
holster
3 year warranty
Specifications
Function Range Accuracy Resolution
Insulation Resistance
Auto ranges 4.000 M, 40.00 M, To 100 M: 2% + 2 counts 0.001M to 10 M
400.0 M, 4000 M Over 100 MΩ: 10% + 2 counts +1%/G
Test voltages 250V, 500V, 1000V +20%, -0%
Max measurement current 1 mA
Audible/visible voltage warning 30V ac or dc
Lo-Ohms
Resistance O to 40.00 2% + 2 counts 0.01
Analog bar graph 0 to 100
Audible/visible voltage warning 30V ac or dc
Resistance
Resistance 4 k 2% + 2 counts 1
Analog bar graph 0 to 10k
Voltage
Voltage 0 to 600V ac (50/60 Hz) 2% + 2 counts 1V
0 to 600V dc
The Fluke 1520 MegOhmMeter is a
handy insulation resistance tester that
also measures voltage and checks
connections with its Lo-Ohms function.
600V
CAT III
Designed and
Conforms to
IEC 61010-1
R
LISTED
950Z

Other manuals for Fluke 1520