EasyManua.ls Logo

Fluke 1587 - Model Output Voltage Specifications; Model 1587;1587 FC Output Voltage Specs; Model 1577 Output Voltage Specs

Fluke 1587
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Insulation Multimeter
Electrical Specifications
41
Model 1587/1587 FC
Output Voltage Display Range Resolution Test Current
Resistance Accuracy
±(% of Rdg + Counts)
50 V
(0 % to +20 %)
0.01 to 6.00 MΩ 0.01 MΩ
1 mA @ 50 k ±(3 % + 5 counts)
6.0 to 50.0 MΩ 0.1 MΩ
100 V
(0 % to +20 %)
0.01 to 6.00 MΩ 0.01 MΩ
1 mA @ 100 k ±(3 % + 5 counts)
6.0 to 60.0 MΩ 0.1 MΩ
60 to 100 MΩ 1 MΩ
250 V
(0 % to +20 %)
0.1 to 60.0 MΩ 0.1 MΩ
1 mA @ 250 k ±(1.5 % + 5 counts)
60 to 250 MΩ 1 MΩ
500 V
(0 % to +20 %)
0.1 to 60.0 MΩ 0.1 MΩ
1 mA @ 500 k ±(1.5 % + 5 counts)
60 to 500 MΩ 1 MΩ
1000 V
(0 % to +20 %)
0.1 to 60.0 MΩ 0.1 MΩ
1 mA @ 1 M
±(1.5 % + 5 counts)
60 to 600 MΩ 1 MΩ
0.6 to 2.0 GΩ 100 MΩ ±(10 % + 3 counts)
Model 1577
Output Voltage Display Range Resolution Test Current
Resistance Accuracy
±(% of Rdg + Counts)
500 V
(0 % to +20 %)
0.1 to 60.0 MΩ 0.1 MΩ
1 mA @ 500 kΩ ±(2.0 % + 5 counts)
60 to 500 MΩ 1 MΩ
1000 V
(0 % to +20 %)
0.1 to 60.0 MΩ 0.1 MΩ
1 mA @ 1 MΩ ±(2.0 % + 5 counts)
60 to 600 MΩ 1 MΩ

Other manuals for Fluke 1587

Related product manuals