Do you have a question about the Fluke 1587 MDT and is the answer not in the manual?
Category | Multimeter |
---|---|
Model | 1587 MDT |
DC Voltage Range | 0.1 mV to 1000 V |
Resistance Range | 0.1 Ω to 50 MΩ |
Insulation Test Voltages | 50 V, 100 V, 250 V, 500 V, 1000 V |
Diode Test | Yes |
Continuity Test | Yes |
Safety Rating | CAT III 1000 V, CAT IV 600 V |
Type | Digital |
Capacitance Range | 1 nF to 10, 000 µF |
Insulation Resistance Range | 0.01 MΩ to 2 GΩ |
Battery Type | AA |
Dimensions | 200 x 100 x 50 mm |
Temperature Range | -40 °C to 200 °C |
Overview of the Fluke 1587 FC, 1587, 1587T, and 1577 insulation multimeters.
Contact information for Fluke support, calibration, and repair services.
Identifies hazardous conditions and procedures to prevent user injury or equipment damage.
Lists included and optional accessories for the product.
Alerts users to the presence of potentially hazardous voltages.
Explains the Meter's automatic sleep mode for battery conservation.
How to turn on the Meter and select measurement functions via the rotary switch.
Explains the function of each button for feature activation and mode selection.
Details the various symbols and codes displayed on the Meter's screen.
Diagram and description of the Meter's input terminal connections.
How to activate special features by holding buttons during power-on.
How to use AutoHold to capture stable readings automatically.
Records minimum, maximum, and average values during measurements.
Explanation of Auto Range and Manual Range selection.
Explains AC zero input behavior and VFD low-pass filter function.
Introduction to performing basic measurements with the Meter.
Instructions and illustrations for measuring AC and DC voltages.
How to measure temperature using the included type-K thermocouple.
Instructions for measuring electrical resistance.
Instructions for measuring capacitance.
How to use the continuity test with audible beeper feedback.
Procedure for testing diodes to determine if they are good or bad.
Steps and safety precautions for measuring current.
Detailed guide on performing insulation resistance tests on dead circuits.
Explanation of Polarization Index and Dielectric Absorption Ratio tests.
How to measure signal frequency using the Meter.
Overview of the wireless system for connecting test tools to apps.
Instructions for cleaning, battery testing, and fuse testing.
Procedures and safety warnings for replacing batteries and fuses.
Technical specifications including size, weight, and operating conditions.
Accuracy and range details for AC voltage measurements.
Accuracy and range details for Low-Pass Filter voltage measurements.
Accuracy specifications for the 1577 model's AC voltage measurement.
Accuracy specifications for DC voltage measurement across models.
Accuracy specifications for DC millivolts measurement.
Accuracy and burden voltage for DC and AC current measurements.
Accuracy and overload protection for resistance measurements.
Specifications for diode testing and continuity testing.
Accuracy specifications for frequency measurements.
Sensitivity and trigger levels for frequency counting.
Accuracy specifications for capacitance and temperature measurements.
Measurement ranges, test voltages, and current for insulation tests.
Resistance accuracy details for 1587/1577 models at various test voltages.
Resistance accuracy details for the 1587T model.
Resistance accuracy details for the 1587C FC model.