Electrical Installation Tester
Specifications
73
Specifications
General Specifications
Size ......................................................................... 10.0 cm (L) x 25.0 cm (W) x 12.5 cm (H)
Weight (with batteries) ............................................ 1.3 kg
Battery .................................................................... 6 x AA Alkaline IEC LR6
Usable with 1.2 V NiMH batteries (not
included)
Battery life (typical) ................................................. 200 hours idling
Fuse ........................................................................ T3.15 A, 500 V, IR: 1500 A
Operating Temperature .......................................... -10 °C to +40 °C
Storage Temperature .............................................. -10 °C to +60 °C (limited by battery
specification)
-40 °C for 100 hr
Relative Humidity .................................................... 80 % 10 °C to 35 °C
70 % 35 °C to 40 °C
Altitude
Operating ............................................................ 2 000 m
Storage ............................................................... 12 000 m
Vibration .................................................................. MIL-PRF-28800F: Class 2
Ingress Protection ................................................... IEC 60529: IP 40
Safety
IEC 61010-1 ........................................................ Pollution Degree 2
IEC 61010-2-030 ................................................ 300 V CAT IV, 500 V CAT III
Maximum voltage between any
terminal and earth ground ................................... 500 V
IEC 61010-031 (Accessories)
TP165X Remote Probe with cap .................... CAT IV 600 V, CAT III 1000 V, 10 A
TP165X Remote Probe without cap ............... CAT II 1000 V, 10 A
TL-L1, TL-L2, TL-L3 Test Leads ..................... CAT IV 600 V, CAT III 1000 V, 10 A
Test Probes with cap ...................................... CAT IV 600 V, CAT III 1000 V, 10 A
Test Probes without cap ................................. CAT II 1000 V, 10 A
AC285 Alligator Clip ....................................... CAT IV 600 V, CAT III 1000 V, 10 A
Country-Specific Mains Cord .......................... CAT II 250 V, 1000 V dc

Table of Contents