EasyManua.ls Logo

Fluke 1664 FC - Earth Resistance Display;Dial and Terminal Settings

Fluke 1664 FC
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1662/1663/1664 FC
Users Manual
56
To measure earth resistance:
1. Turn the rotary dial to the position. See Table 18.
Table 18. Earth Resistance Display/Dial and Terminal Settings
hwl010.eps
Push
Button
Action
1664 FC
1663
1662
Start the selected test
2. Press and release . Wait for the test to complete.
The primary display shows the earth resistance reading.
Voltage detected between the test rods shows in the secondary
display. If >10 V, the test is inhibited.
If the measurement is too noisy, Err 5 shows on the display. (The
measured value accuracy is degraded by the noise). Press
to show
the measurement. Press to return to the Err 5 display.
If the probe resistance is too high, Err 6 shows. Probe resistance may
be reduced if you push the test stakes further into the earth or apply
water to the earth around the test stakes.