14
TS100 Cable Fault Finder
Users Guide
If Something Seems Wrong
with the Tester
The display remains at 8.8.8.8. after power on.
The self test has failed. The batteries may be weak or
the tester has water inside. Try changing the batteries
or drying the tester.
The tester reads less than 10 feet (3 meters)
regardless of the length of the cable.
The connection to the cable is broken. Check your
connection to the cable for dirt or insulation. Also, test
the clip leads by shorting them and listening for the
beeper. You can also visually check the center
connection of the BNC for damage.
The tester does not respond to any button presses.
The batteries could be dead or inserted incorrectly, or
the contacts are dirty or broken. Please ensure that
nothing is connected to the input connector before
opening the battery door, and then check the battery
installation. Remove the batteries and check the
contacts for dirt or damage. Please observe correct
polarity when inserting the batteries.
Maintenance
WXWarning
These servicing instructions are for use by
qualified personnel only. To avoid electric
shock, do not perform any servicing other
than that contained in the operating
instructions unless you are qualified to do
so.
Disconnect clips from any metallic
connections before performing any
maintenance.
WCaution
Do not use CRC Cable Clean
®
or any similar
chlorinated solvent on the TS100. Doing so
will damage the TS100.
There are no user serviceable components or adjust-
ments in the TS100. Do not open the housing as
handling of the PC board could remove the moisture
protection coating or apply a static charge that will
damage sensitive components.
Note
Opening the housing will void the warranty.
Moisture will not harm the tester. However, moisture
can provide a leakage path that may conduct
hazardous voltages to you. DO NOT USE the tester if
wet.
If moisture should get inside the tester, let the tester
dry at normal room temperature for 24 hours. DO NOT
HEAT THE tester.
The tester may be cleaned by using a soft cloth with
soap and water. Do not use a petroleum-based or
chlorinated cleaning agents.