EasyManuals Logo

Fluke 51 Series User Manual

Fluke 51 Series
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
51 & 52 Series II
Users Manual
14
General
Weight 280 g (10 oz)
Dimensions
(without
holster)
2.8 cm × 7.8 cm × 16.2 cm
(1.1 in × 3 in × 6.4 in)
Battery 3 AA batteries
Certification P, ) s
Safety CSA C22.2 No. 1010.1 1992
EN 61010 Amendments 1, 2
CAT I OVERVOLTAGE (Installation)
CATEGORY I, Pollution Degree 2
per IEC1010-1*
* Refers to the level of Impulse Withstand Voltage protection
provided. Equipment of OVERVOLTAGE CATEGORY I is
equipment for connection to circuits in which measures are
taken to limit the transient over voltages to an appropriate low
level. Example include protect electronic circuits.
80 PK-1 Thermocouple (supplied with
thermometer)
Type Type K, Chromel Alumel, bead style
Temperature
Range
40
o
C to +260
o
C
(40
o
F to +500
o
F)
Accuracy ± 1.1
o
C (± 2.0
o
F)
Electrical
Measurement
Range
J-type: 210
o
C to +1200
o
C
(346
o
F to + 2192
o
F)
K-type: 200
o
C to +1372
o
C
(328
o
F to +2501
o
F)
T-type: 250
o
C to +400
o
C
(418
o
F to +752
o
F)
E-type: 150
o
C to +1000
o
C
(238
o
F to +1832
o
F)
Display
Resolution
0.1
o
C /
o
F / K < 1000
o
1.0
o
C /
o
F / K 1000
o
Downloaded from Elcodis.com electronic components distributor

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 51 Series and is the answer not in the manual?

Fluke 51 Series Specifications

General IconGeneral
Data LoggingNo
Power Supply9V battery
Operating Temperature0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature-20 °C to 60 °C (-4 °F to 140 °F)
Temperature Range-200 °C to +1372 °C (-328 °F to +2501 °F)
Resolution0.1 °C / 0.1 °F
Thermocouple CompatibilityJ, K, T, E
Battery Life200 hours (typical)