Advanced Display
100-point onboard temperature
data logging capability
30 preset common material
emissivity values
Adjustable emissivity values
(0.01 increments)
Customizable log names, alarms,
and emissivity
574-NI Nonincendive
Model
When safety is a concern and
data logging and downloading
are required, the Fluke 574
Nonincendive (NI) model
thermometer is the product to
choose. It has the same great
features as the standard 574
model thermometers with the
extra confidence of a Factory
Mutual approval for use in
hazardous environments*.
The Fluke 574-NI thermometer,
does not to release enough electrical or thermal energy to
ignite flammable gases or vapors under normal operational and
environmental conditions.
*See specification table for details.
Advanced Sighting
Accurate measurements depend in part on
accurately sighting a target. Fluke 570 series
thermometers are the only thermometers with
a sighting system designed to precisely track
the infrared path as seen by the sensors. This
enables the advanced coaxial three-dot laser
sighting to accurately show both the center
and the edges of the spot being measured,
regardless of the thermometer’s distance from
the target.
This laser sighting also appears twice as
bright to the human eye as normal lasers
(while maintaining the same safety rating as
less bright lasers), making precise sighting
easier in a variety of lighting conditions and
distances.
Close Focus Option
The Close Focus (CF) option lets you accurately measure very
small areas at the focus point – where the IR beam narrows.
Paired with the advanced coaxial laser sighting system,
extremely small objects 6 mm (0.24 in) at 300 mm (11.4 in)
can be easily measured. Ideal for electrical maintenance and
refrigeration troubleshooting.

Other manuals for Fluke 572

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 572 and is the answer not in the manual?

Fluke 572 Specifications

Temperature IconTemperature
temperature range-30 to 900°C (-25 to 1600°F)
ambient operating range0 to 50°C (32 to 122°F)
storage temperature-20 to 50°C (-4 to 122°F)
Display IconDisplay
display resolution0.1°C (0.2°F)
accuracy at 25°C± 0.75% of reading or ± 1K (± 1.5°F)
repeatability±0.5% of reading or ±1°C (±2°F)
Power IconPower
power2 x 1.5 V Alkaline Type AA
battery life13 hrs. (50% laser and 50% backlight used)
response time (95%)250 mSec
Dimensions IconDimensions
dimensions200 x 170 x 50 mm (7.9 x 6.7 x 2 inches)
tripod mount1/4”-20 UNC
optical resolution (standard focus)60 : 1 (19mm spot size at 1.15M)