DSP-100,DSP-2000 Users Manual Supplement
7/00 3
Table 3-1. Wire Map Displays (continued)
Short
gc51i.eps
Wires 1 and 2 are shorted. You can
use the TDR test to locate the short.
Open
gc53i.eps
Wire 1 is not connected from end to
end or "open". You can use the TDR
test to locate the open.
Split pair
gc55i.eps
A wire in the 3,6 pair is twisted with a
wire in the 4,5 pair. You can use the
TDX analyzer to locate the split pair.
On page 7-23, Table 7-1, replace the entire first column and the bottom two
cells of the second column with the following:
gc53i.eps
Wire map display showing an
open on pair 1, 2.