DSP-100/2000
Users Manual
2-10
Autotest on Coaxial Cable
The following tests are run during an Autotest on coaxial cable:
Impedance
Resistance
Length
Anomaly detection (Results shown only if anomalies are detected.)
To run an Autotest on coaxial cable, refer to Figure 2-3 and proceed as follows:
1. Turn off any PC nodes connected to the cable you are testing.
2. If you want the Autotest to report cable length, remove the terminator from the
far end of the cable.
3. Turn the rotary switch to AUTOTEST.
4. Verify that the test standard and cable type displayed are correct. You can
change these settings in the SETUP mode.
5. Remove any cable connected to the test tool’s unused RJ45 connector.
6. Remove the terminator from the near end of the coaxial cable and connect the
cable to the BNC connector on the test tool. On Model DSP-2000, use the
RJ45 to BNC adapter to connect the cable to the CABLE TEST jack.
7. Press T to start the Autotest.