Running Individual Tests
Single Test Results for Twisted Pair Cable
4
4-13
Wire Map
Wire map results are identical to the Autotest version. See “Wire Map” in Chapter
3 for details. The Single Test version of the wire map test includes the scanning
function.
Length
If a remote is connected, the length test and results are identical to the Autotest
version. See “Length” in Chapter 3 for details.
If a remote is not connected, the test tool displays the message
NO REMOTE DETECTED, and the limit and result columns are not shown. If
the length of a cable pair cannot be determined, the length value on the display is
blank and WARNING appears in the result column.
NEXT and NEXT@REMOTE
The NEXT test and results are identical to the Autotest version. See “NEXT” in
Chapter 3 for details.
The NEXT@REMOTE test is available only when using a second main DSP-100
unit or a smart remote as a remote unit. Remote end testing must be enabled on the
main unit. The NEXT@REMOTE test and results are identical to the Autotest
version. See “NEXT@REMOTE” in Chapter 3 for details.
Impedance
The impedance test and results are identical to the Autotest version. See
“Impedance” in Chapter 3 for details.
Attenuation
The attenuation test and results are identical to the Autotest version. See
“Attenuation” in Chapter 3 for details.
Resistance
If a remote is connected, the results displayed are identical to the display in
Autotest. See “Resistance” in Chapter 3 for details.
If a remote is not connected, the test tool displays the message
NO REMOTE DETECTED and all pair resistances are reported as OPEN. A
cable pair with a resistance greater than 400 is also reported as OPEN.