Ping / LinkRunner Configuration
Press both action buttons simultane-
ously to access configuration (Ping
or
LinkRunner
). If no
cable is connected, press
to
access Configuration.
Ping Configuration
Press
to configure IP
addresses for pinging.
Press
to highlight an
item.
- press
for
DHCP on/off.
Note: manual IP address configuration changes will be
ignored until you turn off DHCP.
User-defined IP Addresses
- press
to enter user-defined IP addresses
(up to 4 common IP address ping targets).
Press to cycle through ping targets 0 - 4. Tar-
get 0 means you don’t want to ping a target.
Press
to access IP edit-
ing then press
to begin
editing the selected target.
Entering an IP Address
Press
to increment
each digit.
Press
to advance.
Press to exit.
Note: Invalid addresses revert to the previous value
(class D, E, 0.0.0.0, or 255.255.255.255).
- press to access IP
Configuration.
Press to highlight an
address:
LinkRunner IP address
Subnet Mask
Default Router
Manual IP
Configuration
Press the right selection button
to begin editing an address.
Press to then .
LinkRunner
Configuration
From the Ping/LinkRunner
Configuration screen, press
LinkRunner Configura-
tion.
Displayed are the LinkRunner
MAC address and version.
Press to select feet or
meters.
Press to exit.
Other Features and Functions
Unpowered
Device
Token Ring
Telco
No DHCP
Server found
Auto-off: unit powers off after 5 minutes of inactivity
(auto-off disabled during ping or cable locate tasks).
Restore Factory Defaults: press power button as you
press both selection buttons.
Ping Responder: In ping mode LinkRunner responds
to pings from other devices.
Duplicate IP
addresses found
Help Technical Assistance Center
Have a question about using LinkRunner? Contact the
Technical Assistance Center at one of the numbers
listed or e-mail: support@flukenetworks.com.
USA
1-800-283-5853 Japan +81-3-3434-0181
Canada
1-800-363-5853 China +86-10-6512-3435
Europe
+31-402-675-200 Singapore +65-6-738-5655
Anywhere +1-425-446-4519
You can also visit the Fluke Networks Knowledge Base
at http://kb.flukenetworks.com.
Accessories
Buy LinkRunner accessories or other network test
products by contacting a Fluke Networks representa-
tive or send e-mail to: sales@flukenetworks.com. For
more information go to
www.flukenetworks.com/linkrunner.
Accessories Part No.
Cable ID Kit (IDs 1-8) 1665935
Clip Set 1668377
Toner Receiver 1667985
Wiremap Adapter (ID #0) 1668404
Rechargeable Batteries 1572184
Battery Charger 1572191
RJ-45 Coupler 1668361
Cleaning Clean unit with a damp cloth.
h
Caution If the equipment is used in a manner not
specified by the manufacturer, the protection
provided by the equipment may be impaired.
Warranty
LinkRunner carries a one-year warranty. Find
out more at
www.flukenetworks.com/linkrunner.
Specifications
P
European directive
Meets EN61010-1 1
st
and 2
nd
editions.
Meets EN61326 Class A, for ESD criteria C, FCC part 15
Class A.
$
Canadian Nationally Recognized Test Laboratory for U.S.
and Canada
Meets CSA/CAN C22.2 No.1010.1-92, UL3111-1.
j
Not intended to be connected to telecommunication line.
;
N10140
Meets C-Tick EMC standard.
?