FZR Series 00939124R00 Speci cations 3
Welcome to Follett
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and outstanding
after-the-sale support. To ensure that this product delivers that same degree of service, we ask that you take a moment
to review this manual before beginning the installation. Should you have any questions or require technical help at any
point, please call our technical service group at (800) 523-9361 or (610) 252-7301.
Before you begin
After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If damage
is found, notify the shipper immediately and contact Follett Corporation so that we can help in the ling of a claim, if
necessary.
Check your paperwork to determine which item number you have. Follett item numbers are designed to provide
information about the type of freezer you are receiving. Following is an explanation of the different item numbers.
Model Number Item Number Stackable/Use with
Pedestal*
FZR5 FZR5-000000
FZR5-00ST00 X
FZR4-ADA FZR4-000000
FZR4-00ST00 X
Speci cations
Series speci cations
FZR5 34" (864mm) high ts below standard 36" (915mm) high counter 4.0 cu ft (1.2 cu m) capacity
FZR4-ADA 31.25" (794mm) high ts below 34" (864mm) high ADA-compatible
counter
3.3 cu ft (1.0 cu m) capacity
Electrical speci cations
115V, 60Hz, 1 phase
Full load amps: 8.0
Minimum circuit ampacity: 15 amp
Maximum size of branch circuit overcurrent device: 15 amp
Refrigeration speci cations
Refrigerant – R404A
Charge size – 10 oz
Maximum design pressures: High side – 383 psi; Low side – 175 psi
Installation speci cations
Ambient temperature must not exceed 86 F (30 C). Relative humidity 60%.
The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of the
refrigeration system.
CAUTION
• Equipment must be wired according to local NEC codes.
• Unplug equipment before servicing.
• Be sure to nd adequate storage for products prior to unplugging equipment.