No any working for openers
1. Power supply
2. Plug wire are loosing
1. Check the power supply from electronic plug on
openers.
2. Carefully open the opener cover, check all plug wire on
control boards.
Not working for opener,
Display shows
Faulty learning on “Up”
Or “Down” limit travelling
Lean “Up” and “Down” limit travelling again follow the manual
Door is up moving only.
Do not work in down moving and the
display show
Photo cell function has been effective
but without connecting any photo cell device.
Turn off the photo cell function if there is no any
photo cell device connected.
( Refer the instruction manual)
Up and Down moving is reversed
Reversed plug wire between gear motor and
board
※ Power off firstly, open the cover and reverse the plug
wire between gear motor and board. Re-set limit
travelling.
Door was Automatic reversed 15-40cm
before the door closed completely
In operation with automatic reversed
function. Because of some old
doors with not good balanced spring
or some block on it’s moving.
1. Check the door springs or any block position.
2. Re-set the limit travelling
3. Increase the force number for automatic reverse.
Transmitter is not working
1. Flat battery
2. Antenna is loosed or not well extended.
3. Interference around nearby
1. Replace new battery.
2. Extend the antenna on the opener
3. Get rid of interference
Cannot code in the new remotes
1. Stored remote code has been full
2. New remote is not compatible with
opener
1. Press “code” button over 8 Sec until LED
displays “C”, deleted all stored codes, code in new remotes
again.
2. Choose our remotes only.
Display shows
Opener does not work.
1. loosing for gear motor plug wire
2. Damage for gear motor
3. Damage for control board
1. Re-insert plug wire on gear motor
※2. Replace new gear motor
※3. Replace new control board
Display shows
After Opener was moving several
centimeters only
1. Hall sensor wire plug was loosing between
hall sensor and board.
2. Hall sensor or board is damage
1. Check the wire plug
※2. Check the hall sensor
※3. Replace control board
Remark: Only the professional person who are qualified to carry out the installation with ※ marked.