24
Service / Repair
Electrical troubleshooting
In the event that neither the heater nor the pump will work check that your supply is OK.
Check the fuse located under the IEC inlet socket on the left of the machine. A spare is fitted in the small
plastic fuse holder. The fuse is a standard 20mm x 5mm glass fuse. It is rated at 5 Amps.
If neither the fuse nor the mains supply are faulty then turn off the machine. Unplug the machine from the
mains and remove the iec plug from the side of the machine and follow below:
IEC inlet socket on the left of the machine. Spare is fitted in the small plastic fuse holder.
Remove the 6 self-tapping screws retaining the rear panel.
Before any maintenance work is carried out, electrical supply must be locked in the OFF position
or the mains lead removed.
Only a qualified electrical technician may work on any parts carrying mains voltage and should be
responsible for ensuring that the machine is in a safe condition before allowing services to be res-
tored.