FUNCTION
FUNCTION
MODE 1
MODE 2
MODE 3 MODE 4
MODE 5 +
MODE 6 +
15
Smart Arming
Smart Doorlock
Smart Lock pulse
Disable
Automatically LO CK
and rearm alarm if
door(s) are not opened
Automatic Lock when
starter kill arms.
Lock pulse only when its
Unlock
— —
16 Cold Start Timer 3 hours at -5
o
c/Runtime
o
3 hours at -5
o
c/5 minutes
o
Cold time OFF —
17 Domelight Delay Disable
trigger (dome light)
when arming or
— — — —
18 Diesel Mode Disable
Delay between Ignition
power up and Starter
Delay between Ignition
power up and Starter
No delay between
Ignition power up and
— —
20
-Tachless - -analog
tach- -Tach Data-
Tachless on crank and
supervision Tach Data-
Link or analogic after
( vehicles with
automatic transmission
Analog Tach learning
(see p.4 for programming)
on tachless. (
vehicles with automatic
Supervision by
Data-Link Tach (Data
Tach Data-Link
only (Data interface
required)
21 Start Attempts 2 1 3 — — —
22
FUNCTION
Start: (button 4) 1 sec.
Stop: (AUX --> button
4) 1 sec.
Start : (button 4) 3 sec.
Stop : (AUX --> button
4) 1 sec. 1-way remote
Option alarm active
2-way remote Battery
saver
Start:(AUX --> button4)
1sec. Stop : (button 4) 1
sec.1-way remote only
— —
23 Master RESET
options by default.
(Retains already
programmed remote.)
— — — — —
24
Disable Application 1 Application 2 Application 3 — —
25
Auxiliary 1 Output
AUX--> LOCK
0.5 seconds &
disarm alarm
0.5 seconds
10 sec latch or
until a button is pressed.
20 sec latch or
until a button is pressed.
until a button is
Latch until shutdown
27
Auxiliary 2 Out-
putAUX--> UNLOCK
0.5 seconds &
disarm alarm
0.5 seconds
10 sec latch or until a
button is pressed.
20 sec latch or until a
button is pressed.
—
28
Neutral safety switch
No application Enable (see p.4)
For manual transmission vehicles equipped with neutral safety switch. DO NOT CUT THE LOOP.
Connect the auxiliary IN (Purple/White) to the neutral safety switch of the vehicle.
30 Valet code
Ignition ON
Valet button x3 times.
Valet button x3 times
and x1 times 3
Ignition ON
Valet button x4 times
and x1 times 3 seconds.
Ignition ON
Valet button x5 times
and x1 times 3 seconds.
Valet button x6
times and x1 times 3
Ignition ON
Valet button x7 times
and x1 times 3 sec.
31
Special application
Programmable
output (+)
No special application
Priority on function 2
Special application - Function 2 (all option)
not available.
— —
disable with vehicle
White wire (5th relays):
Trunk output(+)
White wire (5th relays):
(+)Parking light output
32
Conguration
Dk.Blue (Pin17)
Yellow/Red (Pin19)
wire
Pin17): Shut-down 1
second after remote
start run time.
------------------
Dk.Blue (Ground out,
Pin17): Shut-down 3
seconds after remote
start run time.
Yellow/Red (Pin19) (Arm):
Shutdown after
— — —
33
Manual transmission
function
starter remote.
by hand-brake and Foot
completed by locking the
Cancel ready mode
when trunk open.
— —
34 Trunk output Pulse 0.5 seconds Pulse 2.5 seconds
Unlock before trunk pulse
0.5sec
Trunk Output at ignition
only
— —
35
Door unlock Special
application
No special application
Activate vehicle ignition
at unlock.
Activate vehicle ignition
and accessory at unlock.
— — —
36
Activation/
desactivation remote
Valet Mode
by remote :
LOCK + UNLOCK
or Valet button.
AUX --> Lock + Unlock
By Valet button only — — —
37
Security Remote car
starter
Special application
No special application
Engine if the door
is opened before
UNLOCK is pressed.
— — — —
38
System control by
OEM Remote
Disable
Enable (Press 3x Lock
to remote start) (Bypass
module required)
—
Enable
Alarm controled by OEM
Remote.
Unlock Lock to remote
start) (Bypass module
—
39
AUX1 CONTROLED
BY Temperature
Disable
at +5
o
c when remote
started (see function
— — — —
LEGEND: FUNCTION BY DEFAULT