Green light ----- Success , Red light------Fail or haven’t adjust frequency, Orange light----
----User does not put IC into socket
In addition,in order to prevent omitting to write,the writer is added with the lid open
detection function after successful writing.If the blue light is on,it means user opens the
lid after writing,or puts IC back in Socket without pressing RUN Key. The status is
shown as below:
Chart 1-3-2-3
P.s. Above version v1.0.6, there’s a new function that user can limit the max
number of writing.
The number upper is the max number that user can write. The number lower is the
number that user has written.
Chart 1-3-2-4
1.3.3 CRC Verify Mode
CRC Verify Steps
Before Power on again, make sure SW1 is switched to Low, but SW2 and SW3
Rev_V1.8 11 / 20 www.fortiortech.com