8
Connecon to the water supply and drain
Install the water connecon before the electrical connecons.
Connect the 3/4” supply pipe (supplied) to the machine and to the cold
water supply.
For praccal and safety purposes, it is advisable to install a shut-o valve (not
supplied) (g 1: 1.Switch; 2.Socket; 3.Electrical Plug; 4.Water
Supply (one per unit); 5.Valve; 6. Water drain from the container: 7.Water
drain with open siphon.). Apply the exibile pipe (supplied)with a 20mm
inner diameter and of adequate length (not more than 1 metre from the
machine) to the water drain ng of the machine.
3
Install the machine so that the venlaon of the cooling unit is not
obstructed in any way.
Avoid installaon in a dusty enviroment, this can block the cooling condenser
and prevent the machine from operang.
To prevent the ice from becoming contaminated , never store food, boles,
etc in the container.
Do not leave the ice container open, unless retrieving ice.
6
7
Min 10˚C (50˚F)
Max 32˚C ( 90˚F)
H
2
O
Max 0,5 M Pa
(5bar)
Min 0,1 MP a (1bar)