Cleaning and maintenance
Disconnect the electrical power supply from the appliance to perform maintenance and
cleaning operaons
Use a cloth dampened with a specic chlorine-free product for stainless steel to clean the case.
Cleaning the air condenser.
To maximise the eciency and life of you machine, the condenser at the front of the machine must cleaned
periodically (Fig 6)
Do not use wire brushes or blunt objects to clean the condensor, use a so brush or vacuum with a suitable
nozzle. Where a condenser requires cleaning with a cleaner other than a brush or vaccum. This should be
out by competent engineer.
Cleaning the water inlet lter
It is recommended that this is carried out by a competent engineer.
Close the water shut-o valve, disconnect the water inlet pipe and remove the lter valve with a pair of
pliers.
Clean the lter with a water jet and then reassemble it.
6
Malfuncon
In the event of a Fault, it is recommended to disconnect the electrical and water supply
1. Check that the water supply tap is on.
2. Check that power, that the plug is correctly inserted, and that it is switched on and the fuse has not
failed
3. Check that there are no abormal vibraons.
4. If there is a water leak, stop the machine rst before making any adjustments.
5. If ice producon is low, check that the condenser is clean, check for the build up of limescale
accumulaon of the sprayer nozzles.
6. To Check that the cabinet sensor is working: rest an ice cube on the bulb inside the container. This
should stop ice producon within 1 minute, when the cube is removed. Ice producon should
restart within 1 minute.
7. Between summer and winter the cabinet thermometer may vary the maximum quanty of ice in
the cabinet, in order to adjust this value, contact an authorised installer.
6