Shelf Supports
The unit has sloed removable shelf supports allowing exible shelf posioning. Ensure the trayslides/clips
are ed parallel and level.
When loading product onto the shelves ensure that it does not overow the rear and sides as this will
restrict airow throughout the cabinet.
Lighng
Where ed the light can be turned on or o by pressing and releasing the buon.
Load/Product Distribuon and Airow
Product should be evenly distributed throughout the cabinet or counter.
For both cabinets and counters, no more than 40kg should be placed on each shelf, basket or drawer.
Product should be placed in a way that ensures air can circulate around/through it.
4
Cleaning and Maintenance
Important: Before cleaning, the unit should be put into standby and then the power supply should be
turned o at the mains. Please do not plug or unplug the unit with wet hands. Only when cleaning
has been completed and the unit is dry should the cabinet be turned back on at the mains. Using high
pressure water jets or lances is prohibited; the warranty will not cover problems that result from failure
to heed the above warning.
Regular Maintenance:
> As and when required remove all product and shelving (beware of cold and or sharp components)
from the unit. Clean exterior and interior surfaces with mild liquid detergent, following the direcons
on the pack at all mes. Rinse surfaces with a damp cloth containing clean water. Never use wire
wool, scouring pads/powders or high alkaline cleaning agents i.e bleaches, acids and chlorines as
these may cause damage. Dry the unit thoroughly before re-using.
> Cleaning the condenser at least once a month (it is located behind the unitcover); beware of hot
and possible sharp components).
On both the cabinet and counter remove the unit cover securing screw(s) posioned underneath
the front of the unitcover. Pull the cover forward and it will release from the securing pegs to allow
access to the condenser coil.
Once the cover is removed please do not leave the unit unaended. Use a so brush or vacuum
cleaner to remove dirt/dust. If there are any stubborn grease deposits le on or through the
condenser call your supplier to carry out a full service (this is normally chargeable). Failure to
maintain the condenser may invalidate the warranty of the condensing unit and cause premature
failure of the motor/compressor. DO NOT use a wire brush to clean the condenser. Re-t any panels
removed aer cleaning.
> Door gaskets should be inspected on a regular basis and replaced if damaged. To clean, wipe with
a warm damp soapy cloth followed by a clean damp cloth. Finally thoroughly dry before closing the
door.