Loading...
Pans do not become
hot and appears in
the display.
The induction hob cannot
detect the pan because it is not
suitable for induction cooking.
The induction hob cannot
detect the pan because it is too
small for the cooking zone or
not properly centred on it.
Use cookware suitable for induction
cooking. See section ‘Choosing the
right cookware’.
Centre the pan and make sure that
its base matches the size of the
cooking zone.
4. Failure Display and Inspection
The induction hob or
a cooking zone has
turned itself off
unexpectedly, a tone
sounds and an error
code is displayed
(typically alternating
with one or two digits
in the cooking timer
display).
Technical fault.
Please note down the error
letters and numbers, switch
the power to the induction hob off
at the wall, and contact a
qualified technician.
The induction hob is equipped with a self diagnostic function. With this test the
technician is able to check the function of several components without
disassembling or dismounting the hob from the working surface.
Troubleshooting
Failure
code
Problem Solution
Auto-Recovery
E1
Supply voltage is above the rated
voltage.
Please inspect whether power supply
is normal.
Power on after the power supply is
normal.
E2
Supply voltage is below the rated
voltage.
E3
High temperature of ceramic plate
sensor .1#
Wait for the temperature of ceramic
plate return to normal.
Touch “ON/OFF” button to restart
unit.
E4
High temperature of ceramic plate
sensor .2#
E5 High temperature of IGBT .1#
Wait for the temperature of IGBT
return to normal.
Touch “ON/OFF” button to restart
unit.
Check whether the fan runs
smoothly;
if not , replace the fan.
E6 High temperature of IGBT.2#