Troubleshooting
Document Number: TD-104406/0Order Number: 1H329021/0
Machine error codes 5
Error
code
Error text on the
display
Meaning Solution
14 Temperature
sensor
The temperature sensor of boiler 2 (X15) has a
short circuit.
Spectra S: Hot water/steam boiler
Spectra X: Coffee boiler
` Check the connection cable and con-
nection plug.
` Check the temperature sensor and
replace it, if necessary.
` Restart machine.
15 Temperature
sensor
The temperature sensor of boiler 2 (X15) has a
short circuit.
Spectra S: Hot water/steam boiler
Spectra X: Coffee boiler
` Check the connection cable and con-
nection plug.
` Check the temperature sensor and
replace it, if necessary.
` Restart machine.
16 Temp. difference
The temperature in boiler 2 is below the mini-
mum value of 2°C within a heating duration of
60°s.
Spectra S: Hot water/steam boiler
Spectra X: Coffee boiler
Variable: Temperature in °C (actual value when
the error occurred)
` Check the bimetallic thermal switch
(Klixon) and replace it, if necessary.
` Check the electrical circuit.
` Check the temperature sensor and
replace it, if necessary.
` Check the heater.
` Check the connections.
` Restart machine.
17 Over temperature
Boiler 2 temperature is greater than 150 °C or
25 °C above the target value indicated in the
Install menu, see Section 6 - Programming,
V. Programming, 1. Machine, 1.7 Temperatu-
res, p. 34.
Spectra S: Hot water/steam boiler
Spectra X: Coffee boiler
` Check the temperature sensor and
replace it, if necessary.
` Check the heater and replace it, if
necessary.
` Check the connections.
` Restart machine.
` Check the Power PCB
18 Temperature
sensor
The temperature sensor of boiler 1 (X16) has a
short circuit.
Spectra S: Coffee boiler
Spectra X: Hot water boiler
` Check the bimetallic thermal switch
(Klixon).
` Check the temperature sensor and
replace it, if necessary.
` Check the connections.
` Restart machine.
19 Temperature
sensor
The temperature sensor of boiler 1 (X16) is
missing or has been interrupted.
Spectra S: Coffee boiler
Spectra X: Hot water boiler
` Check the temperature sensor and
replace it, if necessary.
` Check the connection cable and con-
nection plug.
` Restart machine.
20 Temp. difference
The temperature in boiler 1 is below the mini-
mum value of 2 °C within a heating duration of
60°s.
Spectra S: Coffee boiler
Spectra X: Hot water boiler
` Check the bimetallic thermal switch
(Klixon) and replace it, if necessary.
` Check the electrical circuit.
` Check the temperature sensor and
replace it, if necessary.
` Check the heater and replace it, if
necessary.
` Check the connections.
` Restart machine.
Boiler heating errors