The sections below describe the updates and known limitations in each firmware version for the FGR2
transceiver models. The most recent version is listed first. The latest firmware versions are available on the
FreeWave Web site at www.FreeWave.com. You can also view the latest firmware available for most models in
Tool Suite. For more information about the additions and updates in each release, see the FGR2 Wireless Data
Transceivers User Manual and Reference Guide.
Version v10.6.7
Release Date: July 2013
Note: If you upgrade from firmware 8.77 or 8.78 to firmware v10.6.7 and experience
issues or inconsistent results, contact FreeWave Technical Support at
303.381.9200 or by email at moreinfo@freewave.com.
Additions and Changes:
l
Corrected problem with serial radios set to RS485 changing to RS232 operation when no setting
change was made. This change only applies to radios that include an RS485 setting for the
serialinterface.
Known Limitations and Work Arounds:
l
In the Network Diagnostics application within Tool Suite, the transceivers report having the incorrect
firmware version installed.
l
In the Operation Mode tab in Tool Suite (Modem Mode menu in the terminal interface), Ethernet
parameters display. These options do not apply to this transceiver.
l
Supply voltage readings within Tool Suite can fluctuate and differ from those readings on an external
voltage meter.
l
When the Use Break to Access Setup setting is set to use the transceiver's current baud rate (a
setting only available through the terminal interface), the Diagnostic port's baud rate does not set to
the default or the Baud Rate setting, resulting in unreadable output. If you use this Use Break to
Access Setup setting, use the data port for configuration.
Version v10.6.6
Release Date: October 2012
Note: If you upgrade from firmware 8.77 or 8.78 to firmware v10.6.6 and experience
issues or inconsistent results, contact FreeWave Technical Support.
Additions and Changes:
l
Updated firmware version to use the vX.X.X format.
l
Added AES 128, 192, and 256 encryption capability. AES functionality is enabled at the factory. To
upgrade an existing transceiver to use the AES functionality, contact FreeWave Technical Support.
You must set AES settings using the terminal interface, as Tool Suite versions 2.9.0.0 and before do
not include AES.
FGR2 Transceiver Firmware Updates
Part Number: LFW0006AA
Revision: B www.FreeWave.com
Last Updated: 07/02/2013 1.866.923.6168 303.381.9200
Question and Answer IconNeed help?

Do you have a question about the FreeWave FGR2 and is the answer not in the manual?

FreeWave FGR2 Specifications

General IconGeneral
Data Rate115.2 kbps
ModulationFHSS (Frequency Hopping Spread Spectrum)
Operating Temperature-40°C to +75°C
Frequency Range902-928 MHz
RangeUp to 60 miles with line-of-sight
Power Output1 W
InterfaceRS-232, RS-485, Ethernet
Operating Voltage6 to 30 VDC
EncryptionAES 128/256-bit

Summary

FGR2 Transceiver Firmware Version v10.6.7

RS485 to RS232 Operation Fix

Corrected problem with serial radios set to RS485 changing to RS232 operation when no setting change was made.

Network Diagnostics Firmware Version Display

In the Network Diagnostics application, transceivers report having the incorrect firmware version installed.

Operation Mode Ethernet Parameters Display

In the Operation Mode tab, Ethernet parameters display, but these options do not apply to this transceiver.

Supply Voltage Reading Fluctuations

Supply voltage readings within Tool Suite can fluctuate and differ from those readings on an external voltage meter.

Diagnostic Port Baud Rate Issue

Diagnostic port's baud rate does not set correctly when using 'Use Break to Access Setup' setting.

FGR2 Transceiver Firmware Version v10.6.6

Updated Firmware Version Format

Updated firmware version to use the vX.X.X format.

AES Encryption Capability Added

Added AES 128, 192, and 256 encryption capability. AES functionality enabled at factory.

Removed Ultra Low Power Mode

Removed the Ultra Low Power Mode feature.

FGR2 Transceiver Firmware Version 8.78

AES Zeroization Support

AES capability now supports zeroization, attempting to hold to NAVSO P5239, and various locks/checks.

Clear 8th Data Bit for 7 Data Bits

Clears the 8th data bit on serial receive when radio is programmed with 7 data bits and parity enabled.

Repeater Timing Fix for OTA Slot

Corrected repeater timing shift issue that could cause link drops on missed packets during firmware upgrades.

Ultra Low Power Mode Parameters

ULPM Enable and ULPM Sleep parameters now available in Transmission Characteristics settings.

FGR2 Transceiver Firmware Version 8.77

Mirror Bits and Multi-Band Master Sync Support

Added support for mirror bits and multi-band master sync.

Mirrored Bit Master/Slave Operation Mode

Allows selection of Mirrored Bit Master or Mirrored Bit Slave as an operation mode.

FGR2 Transceiver Firmware Version 8.73

RS485 Protocol Fix

RS485 Protocol fixed.

Break Command Setup Function Fix

Use Break Command to Enter Setup function fixed.

Grand Master Mode Fix

Grand Master mode (for Multi-Master Sync) feature fixed.

FGR2 Transceiver Firmware Version 8.71

TDMA Settings Write Efficiency

Improved efficiency and reliability of writing TDMA settings to memory.

Diagnostics Settings Write Efficiency

Improved efficiency and reliability of writing Diagnostics settings to memory.

FGR2 Transceiver Firmware Version 8.70

Mirror Back-end Changes

Mirror back-end changes.

FGR2 Transceiver Firmware Version 8.69

Link Acquisition Issue Corrected

Link acquisition issue corrected.

FGR2 Transceiver Firmware Version 8.68 (Initial Release)