The control LED in the instantstart button
lights up green.
X
To switch off: Press the instantstart but-
ton.
The heating mode is switched off.
The control LED lights up white.
i
If alonger remaining time is desired, alon-
ger operating time must be reset. No
changes can be made after aminimum run-
ning time of 10 minutes. An increase is only
possible after switching off and on again.
Setting the preselected heating mode/
timer
You can use the switch clock to set up to
three preselection periods/times per day
(maximum seven days).
If the program time is activated, the auxiliary
heating switches on automatically at the set
time.
i
Only one program time can be activated at
atime.
G
DANGER
If you have preselected aswitch-on time,
the auxiliary heating system switches on
automatically.
R
Toxic exhaust fumes may accumulate if
there is insufficientventilation, carbon
monoxide in particular. This is the case in
enclosed spaces, for example. There is a
risk of fatal injuries.
R
There is arisk of fire and explosion if
there are highly flammable materials or
flammable materials nearby!
If you park the vehicle in these or similar
conditions, alwaysdeactivate the preselec-
ted switch-on times.
Preselection times can only be set when the
heating mode is switched off.
Turn the controller to select afunction or
make asetting and confirm the selection/
setting by pressing the controller.
X
To set the program time: select the
"Timer" menu and confirm.
X
Select the "Add timer" menu item and con-
firm.
X
Select and confirm the day of the week.
X
Set and confirm the desired "Switch-on
time" (hour).
X
Set and confirm the desired "Switch-on
time" (minute).
X
Set and confirm the desired "Switch-off
time" (hour).
X
Set and confirm the desired "Switch-off
time" (minute).
X
Select the 'Heating" function and confirm.
The set timer is saved and shown in the dis-
play.
X
Confirm to activate the timer.
"Activate" is shown in the display.
X
Confirm again.
The "T" symbol is displayed in the main
menu.
The control LED in the instantstart button
flashes green ("Heating" timer active).
Activating, deactivating, editing or delet-
ing the timer
Turn the controller to select afunction or
make asetting and confirm the selection/
setting by pressing the controller.
X
Select the "Timer" menu and confirm.
The saved timers are shown in the display.
X
Select and confirm the desired timer.
X
Select the desired option, e.g. "Manage" and
confirm.
i
If you select the "Delete all" option, "OK" is
shown in the display.Confirm again to
delete all saved timers.
Airflow, air distribution and temperature
If the instantorpreselected heating mode is
active, the blower switches to at least the air
volume level 1.Inaddition, the preset mini-
mum temperature is set.
X
Turn the temperature control to the right
until the maximum temperature is set
(Y page 60).
X
Set the air distribution control and air vents
as required (Y page 58).
X
Set the airflow control while driving as
required (Y page 59).
66
Operating the climate control systems
Climate control