EasyManuals Logo

Friedrich MR09C1H Brochure & Specs

Friedrich MR09C1H
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
HEAT PUMP
Heat pump
S36YF 34100 Btu 14.0 SEER
38200 Btu
Almost 3 ton heat pump for
conditioning large areas
DWC optional, wired, wall-mounted
controller available on ceiling-suspended
model.
MR36Y3F
MS36Y3F
COOL & HEAT
Comfort & Convenience
• LCD wireless remote and secured remote control holder
• Three fan speeds cooling or heating:
high, medium, low, plus autofan
• Multiple operating modes including:
Auto, cool, dry (dehumidi cation), fan only and heat
Long-life, washable air lters
Continuous ‘Air Sweep’ for even distribution of air
throughout the room
• Auto-shut aps close when unit is off
for a sleeker appearance
Auto-restart after power interruptions
• Auto-changeover
• Low temperature operation to 0° F
• Self-diagnostics including stored error codes
• Optional DP-36 condensate pump in lieu of gravity
condensate removal (see accessories)
Fresh air intake (requires a separate in-line fan installation
and ducting)
DRAIN
PUMP
US
ED WIT
H
DP-
36
S3
6Y
F
Drain pump
WIRED
CO
NTR
O
LLE
R
US
ED WIT
H
DW
C
1
8000
Btu and larger
models
a
n
d
all
m
ult
i
zone s
y
stems.
7-day pro
g
rammable
ON
/
OFF timer controls
u
p to 16 un
i
ts
i
nd
i
v
i
du
-
all
y or
b
y zones
.
Wired wall-mounted controller
Refrigeration line sets
Insulated line sets are available for all Friedrich s
p
lit systems in
1
5 ft. and 35 ft. len
g
ths.
Each line set is e
q
ui
pp
ed with
f
lare nuts on both ends. Both li
q
uid
a
nd suct
i
on l
i
nes are
i
nsulated. L
i
ne sets can be
j
o
i
ned to
g
ether
with field su
pp
lied double female connectors.
Each system re
q
uires one line set
f
or each indoor unit installed.
O
n multizone systems, line sets should be ordered based on
i
nd
i
v
i
dual
i
ndoor un
i
t ca
p
ac
i
t
i
es not total system ca
p
ac
i
ty. For
exam
p
le, a M18DYF uses 2 line sets for 9000 Btu units, not 1 for
t
he 1
8000
Btu
p
roduct
.
US
ED WITH
:
L
engt
h
Ft.
L
i
qu
id
Suc
ti
on
K
i
t
#
All
9000
a
n
d
1
2000
B
t
u
i
n
doo
r
u
n
i
t
s
1
5'
1/
4
3
/
8
T
3
21
50
35'
1/
4
3
/
8
T
3
2
350
M
W18C
3
F and
M
W18Y
3
FM indoor
u
nit
s
15'
1/
4
1/
2
T4
2
15
0
35'
1/
4
1/
2
T42
350
M
W24C
3
G indoor uni
t
15'
1/
4
5/
8
T
52
1
50
35'
1/
4
5/
8
T
5
2
350
M
18YH, M24YH,
M
30CG
,
M36CG
,
S2
4YF
,
C2
4YF and
S
3
6YF system
s
15'
3
/
8
5/
8
T
53
1
50
3
5
'
3
/
8
5/
8
T5
33
5
0
Accessories
CEILING-SUSPENDED
11

Other manuals for Friedrich MR09C1H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Friedrich MR09C1H and is the answer not in the manual?

Friedrich MR09C1H Specifications

General IconGeneral
BrandFriedrich
ModelMR09C1H
CategoryAir Conditioner
LanguageEnglish

Related product manuals