RELIABILITY BEGINS
WITH DURABLE
MATERIALS AND THE
HIGHEST QUALITY
COMPONENTS.
Steel base pan and sleeve that are powder-coat
painted to resist rust and corrosion
Outdoor coil and plates are stainless steel to
resist rust and corrosion (other PTACs use lower
grade steel)
Every PTAC unit is run-tested at the factory to reduce
problems in the eld
14 numeric service error codes stored in memory
facilitate rapid unit diagnostics
Easy access, long-life lters simplify maintenance
that extends the life of the product
Room freeze protection- initiates heat if temperature
falls to 40°F in an unoccupied room
Random compressor restart protects electrical
systems from overload when power is restored
Tamper-resistant grille and durable front panel with
break-proof control door design
Indoor coil frost sensor protects the compressor to
lengthen the life of the unit
2 year full warranty on parts and labor; 5 year
limited warranty*
Backed by a nationwide service network, and U.S.-
based Friedrich expert technical team
ENERGY EFFICIENT AND
ENERGY SMART PTACs
• Super ef cient refrigeration design with EERs up to
12.2; COPs up to 3.4
All units are available in energy ef cient heat pump
models
Electronic defrost control ensures more run time in
ef cient heat pump mode
Ability to adjust low/high temperature range limits
for reduced energy usage
Thicker steel inner-wall and foam construction
decreases thermal transfer and energy loss
Condensate removal system uses slinger ring
technology to cool the coil and increase ef ciency
Desk control ready allowing hotel owners to control
units from a central location
Modular design for easy access to key compon
RECEPTACLES AND FUSE TYPES
Voltage 230V 265V
Amps
15 20 30 15 20 30
Heater Size
0, 2.0 kW 3.0 kW 5.0 kW 2.0 kW 3.0 kW 5.0 kW
Receptacles
IMPORTANT NOTE: Sleeves are sold and shipped separately to
accommodate new construction and replacement requirements.
Fits other PTAC sleeves without the added expense of a baffle kit.
Indoor coil frost
sensor protects
compressor
Reversible
louvers for
air path
modi cations
Easy-access,
interchangeable
antimicrobial air
lters
Universal power cord
UNIVERSAL HEATER
POWER CORD
Connect as easily as a phone
jack. PTAC units ship complete
with the standard power cord
for that model (7K, 9K and
12K = 3.0 kW and 15K = 5.0
kW). If you want to adjust the
heater size on any PTAC unit
simply unplug the attached
power cord and connect the
desired size. It is important
to ensure that all wiring and
building connections are
sized properly for the power
cord as well.
Universal heater simplifies
ordering and installation.
For distributors, this means
stockingone PTAC model and
the 2 optional cords in place
of 3 separate PTACs.
REMOTE THERMOSTAT
QUICK-CONNECT WIRING
MODULE
Pulls out and plugs in for easier
wiring during initial installation.
Easier unit change-out; no need
to reconnect and tighten down
thermostat wires.
18

Other manuals for Friedrich MR09C1H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Friedrich MR09C1H and is the answer not in the manual?

Friedrich MR09C1H Specifications

General IconGeneral
BrandFriedrich
ModelMR09C1H
CategoryAir Conditioner
LanguageEnglish

Related product manuals