92016602
W ARNING
15/20A LCDI Device 30A LCDI Device
TEST BEFORE EACH USE
1. PRESS RESET BUTT ON
2. PLUG LCDI INT O POWER
RECEPT ACLE
3. PRESS TEST BUTT ON,
RESET BUTT ON SHOULD
POP UP
4. PRESS TEST BUTT ON,
FOR USE
DO NOT USE IF ABOVE TEST
F AILS
WHEN GREEN LIGHT IS ON
IT IS WORKING PROPERL Y
RESET
TEST
W ARNING
TEST BEFORE EACH USE
1. PRESS RESET BUTT ON
2. PLUG LCDI INT O POWER
RECEPT ACLE
3. PRESS TEST BUTT ON,
RESET BUTT ON SHOULD
POP UP
4. PRESS TEST BUTT ON,
FOR USE
DO NOT USE IF ABOVE TEST
F AILS
WHEN GREEN LIGHT IS ON
IT IS WORKING PROPERL Y
RESET
TEST
FRP014
Electrical Rating Tables
250V Receptacles and Fuse Types
AMPS 15 20* 30
RECEPTACLE
TIME-DELAY TYPE FUSE
(or HACR circuit breaker)
15 20 30
HACR–Heating,AirConditioning,Refrigeration
* Maybeusedfor15Ampapplicationsiffusedfor15Amp
NOTE:265voltunitsarenormallyhardwired.Forproperinstallation
followtheNationalElectricalCode(NEC)orlocalcodesand
ordinances.
FUSE/CIRCUIT
BREAKER
Use ONLY type and size fuse or HACR cir-
cuit breaker indicated on unit’s rating plate.
Proper current protection to the unit is the
responsibility of the owner. NOTE: A time
delay fuse is provided with 265V units.
GROUNDING
Unit MUST be grounded from branch circuit
through service cord to unit, or through
separate ground wire provided on per-
manently connected units. Be sure that
branch circuit or general purpose outlet is
grounded. The eld supplied outlet must
match plug on service cord and be within
reach of service cord. Refer to Table 1 for
proper receptacle and fuse type. Do NOT
alter the service cord or plug. Do NOT use
an extension cord.
RECEPTACLE
The eld supplied outlet must match plug on
service cord and be within reach of service
cord. Refer to Table 1 for proper receptacle
and fuse type. Do NOT alter the service
cord or plug. Do NOT use an extension
cord.
All Friedrich230/208VPTAC units areshipped from thefactorywitha
LeakageCurrentDetectionInterrupter(LCDI)equippedpowercord.The
LCDIdevicemeetstheULandNECrequirementsforcordconnectedair
conditionerseffectiveAugust2004.
Totestyourpowersupplycord:
1. Plugpowersupplycordintoagrounded3prongoutlet.
2. PressRESET.
3. PressTEST(listenforclick;Resetbuttontripsandpopsout).
4. PressandreleaseRESET(listenforclick;Resetbuttonlatches
andremainsin).Thepowersupplycordisreadyforoperation.
NOTE: TheLCDIdeviceisnotintendedtobeusedasaswitch.
Oncepluggedintheunitwilloperatenormallywithouttheneedtoreset
theLCDIdevice.
IftheLCDIdevicefailstotripwhentestedorifthepowersupplycordis
damageditmustbereplacedwithanewsupplycordobtainedfromthe
productmanufacturer,andmustnotberepaired.
Power Cord Information (230/208V models only)
Figure 2
Typical LCDI Devices
NOTE: UseCopperConductorsONLY.WiresizesareperNEC,checklocalcodesforoverseasapplications.
Table 1
WARNING
Electrical Shock Hazard
Turn off electrical power before service
or installation.
ALL electrical connections and wiring
MUST be installed by a qualified
electrician and conform to the National
Code and all local codes which have
jurisdiction.
Failure to do so can result in property
damage, personal injury and/or death.
Installation Instructions POWER CORD ACCESSORY KIT

Other manuals for Friedrich PDE07K