TROUBLESHOOTING
E8 Function Error
Indoor fan error. Check the fan capacitor connection.
Indoor fan high speed(black wire to N terminal)
Normal resistance is around 206Ω. If it is over 1k Ω or less that 10 Ω, that is a broken fan or the fan is under over
heat protection
Check to see if resets after cool down.