COOLING SIZING GUIDE
The cooling guide to the right is based on normal room insulation, average
number of sun-exposed windows and two-person occupancy.
HEATING SIZING INFORMATION
In heating mode, an energy effi cient heat pump will generate slightly less
heating Btus than it would in cooling mode. However, in heating mode, heat
pumps use approximately 1/3 the energy of resistance heat, making them an
excellent high-effi ciency alternative. Back-up resistance heat ensures heat
operation below 40˚ F outdoor temperatures for year ‘round comfort.
Common Window Types
Single/double hung Slider
(Opens up or down) (Opens left to right, or right to left)
Awning Hopper Casement
(Cranks out) (Opens in) (Cranks out)
Traditional wooden windows are typical in many residences built before
1965, but more modern windows are often constructed of aluminum or vinyl.
Many newer energy effi cient windows like double-glazed windows actually
sandwich low conductance gas between two panes of glass. While Friedrich air
conditioners may be used with this type of window, care should be taken not to
break the seal between the two panes of glass during installation.
Depending on the style of window in the application, you may want to consider
the cooling solutions in the adjacent chart. Professional installers may be able
to make fi eld adaptations, including removing all or part of a window to support
alternative types of air conditioning units. Professional installers should also be
able to tell you about any local codes that may apply to your installation.
THRU-THE-WALL INSTALLATION
Many models may be installed through a wall so long as the unit’s side vents are
not blocked or covered in any way. See page 15, In-wall Installation max. depth.
WHICH AIR CONDITIONER
IS RIGHT FOR YOU?
Window Type Air Conditioner
Single/double hung Window, portable,
ductless
Slider Window*, portable,
ductless
Casement Portable, ductless
Vertical Casement Portable, ductless
Awning Portable, ductless
Hopper Portable, ductless
Picture (non-opening) Thru-the-wall,
ductless
*May require additional modifications
COOLING SIZING GUIDE
Area to be conditioned
in sq. ft. Cooling Btu
100 - 150 5000
150 - 250 6000
250 - 300 7000
300 - 350 8000
350 - 400 9000
400 - 450 10000
450 - 550 12000
550 - 700 14000
700 - 1000 18000
1000 - 1200 21000
1200 - 1400 23000
1400 - 1600 25000
1600 - 1900 28000
1900 - 2700 36000
3