7
INSTALLING THE GUARDRAIL
Follow the steps below to install the guardrail.
1. Place the guard rail on top of the cabinet.
2. Align all support feet of the guardrail with the holes on the top of the unit and press down into
place.
INSTALLATION
Installation clearances
Allow the following clearances for ease of installation, proper air circulation, and electrical
connections:
Sides and Top 12.7 cm (5 inches)
Back 12.7 cm (5 inches)
LEVELING
All four casters of your unit must rest firmly on a solid floor. Use adjustable wrench to adjust
leveling screws.
REGULATOR INSTALLATION
• Check to ensure plastic washer is inside the hex nut.
• Fasten the CO
2
regulator (6) to the CO
2
canister (12). Place
the regulator to the right of the tank.
• Tighten the hex nut securely. DO NOT over tighten. Over-
tightening may damage the gasket in the nut of the regulator.
SMALL CO
2
HOSE TO REGULATOR CONNECTION
Attach wing nut on end of small hose (8) to fitting at bottom of regulator (6).
CAUTION: Do not install the unit where the temperature will drop below 13°C
(55°F) or rise above 32°C (90°F). The compressor will not be able to maintain
proper temperatures inside the unit.
NOTE: If your unit is placed with the door hinge side against a wall, you may have
to allow additional space so the door can be opened wider.
CAUTION: do not attempt to move or relocate the keg cooler with a keg inside.