EasyManua.ls Logo

Frigidaire FFAP5034W1 - User Manual

Frigidaire FFAP5034W1
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Frigidaire.com USA 1-800-944-9044 Frigidaire.ca Canada 1-800-265-8352
use
&
care
Dehumidifier
Introduction .....................................................2
Important Safety Instructions ...................3
Location............................................................ 11
How It Works.................................................. 11
Dehumidifier Features................................ 12
Operating Instructions............................... 12
Care And Cleaning ...................................... 17
Storage ............................................................ 18
Normal Sounds ............................................. 19
Before You Call............................................20
Major Appliance Limited Warranty....... 21
Model:
FFAP5034W1
Question and Answer IconNeed help?

Do you have a question about the Frigidaire FFAP5034W1 and is the answer not in the manual?

Overview

This document is a comprehensive user and care manual for a Frigidaire dehumidifier, model FFAP5034W1, providing instructions in English, Spanish, and French.

Function Description:

The Frigidaire FFAP5034W1 is a portable dehumidifier designed to remove excess moisture from the air in enclosed spaces. It operates by drawing in humid air, passing it over dehumidifying coils to condense the moisture, and then discharging dry, warm air back into the room. The collected moisture is gathered in a front-mounted bucket, which can be manually emptied or continuously drained via a hose. The unit is suitable for use in various rooms, including basements, and is particularly effective in enclosed areas where external windows and doors are closed to prevent new humid air from entering. The dehumidifier is equipped with a compressor that has a 3-minute automatic delayed start to prevent overheating and circuit breaker trips.

Important Technical Specifications:

  • Model: FFAP5034W1
  • Power Supply: 115 volts AC outlet (properly grounded, three-prong plug)
  • Refrigerant: Flammable Refrigerant R32 (requires specific handling and servicing procedures)
  • Operating Temperature Range: 5°C (41°F) to 32°C (89°F)
  • Operating Humidity Range: 30% RH to 80% RH
  • Clearance: Minimum 12 inches (30.5 cm) of clearance around the unit for proper airflow.
  • Continuous Drainage Hose: Recommended 1/2 inch (12.7 mm) or larger garden hose. Maximum vertical lift for pump drainage is 5 meters (16.4 feet).

Usage Features:

The dehumidifier features an electronic control panel with several buttons and indicators:

  • ON/OFF Button (D): Turns the unit on or off.
  • Filter Reset Button (A): Indicates when the air filter needs cleaning.
  • Bucket Full Indicator (B): Illuminates when the water bucket is full, causing the unit to shut down.
  • Humidity Display (C): Shows the current room humidity or "CO" in continuous mode.
  • Fan Speed Button (E): Adjusts the fan speed (Hi, Med, Lo).
  • Humidity Adjustment Buttons (F): Allows users to set the desired humidity level (between 35% and 85% in 5% increments).
  • Timer Button (G): Sets a delay start or delay stop time (from 0.5 to 24 hours).
  • Pump Feature Button (H): Activates the pump for continuous drainage.

Operating Modes:

  • CONTINUOUS Mode: The unit runs continuously at high fan speed, displaying "CO" instead of room humidity. This mode is recommended for the first three to four days of operation to eliminate initial dampness and odors.
  • Humidity Set Mode: Users can set a target humidity level, and the unit will cycle on and off to maintain it.

Water Removal Options:

  1. Bucket Emptying: When the bucket is full, the unit stops, and the "BUCKET FULL" light illuminates. The bucket can be gently unclipped from the unit, emptied, and re-inserted. A "click" confirms correct placement.
  2. Continuous Drainage: For constant operation without manual emptying, a garden hose can be attached to the drain connector on the back of the unit. The hose should be directed to a floor drain or other suitable discharge point, ensuring no kinks or blockages.
  3. Pump Drainage (if equipped): For vertical drainage, a pump hose can be connected. The pump allows water to be discharged upwards to a maximum height of 5 meters.

Normal Sounds:

Users may hear several normal operating sounds:

  • Dripping Sound: Water dripping during the dehumidification cycle.
  • Rushing Air Sound: Air movement caused by the fan.
  • Gurgling/Hissing Sounds: Refrigerant passing through the evaporator.
  • High Pitched Chatter: Modern high-efficiency compressors may produce a high-pitched sound.

Maintenance Features:

  • Filter Cleaning: The air filter should be cleaned every two weeks under normal operating conditions. It can be removed from the back grille, washed with clean water, dried, and re-installed. The "Filter Reset" button will illuminate when cleaning is due.
  • Cabinet Cleaning: The exterior can be dusted with a soft, oil-free cloth or a damp cloth. The intake grille can be vacuumed with a brush attachment.
  • Water Bucket Cleaning: The water bucket should be cleaned every two weeks with warm water and detergent to prevent mold and mildew buildup.
  • Pump Filter Cleaning (if equipped): The pump filter should be cleaned every two weeks. This involves removing the water bucket, unscrewing a specific screw (fig. 20), removing the pump drainage assembly, cleaning the filter, and re-assembling.

Safety Precautions:

The manual emphasizes several safety instructions, particularly concerning the use of flammable refrigerant R32:

  • Electrical Safety: The unit must be plugged into a properly grounded, three-prong receptacle. Extension cords or adapter plugs are not recommended. The power cord should not be cut, damaged, pinched, bent, or knotted.
  • Child Safety: Children should be supervised and not allowed to play with the appliance or packing materials.
  • Flammable Refrigerant (R32) Specifics:
    • Servicing must be performed by authorized personnel competent in handling flammable refrigerants.
    • Do not modify the power cord length or use an extension cord.
    • Do not share an outlet with other appliances.
    • Ensure proper ventilation and keep ignition sources away from the unit.
    • Refrigerant must be recovered properly during maintenance or disposal and not discharged into the air.
    • The appliance should be stored in a well-ventilated area corresponding to the room size specified for operation.
  • General Safety: Do not insert fingers or objects into air discharge/grille areas. Do not operate with wet hands. Do not drink collected water. In case of malfunction, disconnect power and call service.

Troubleshooting:

The manual includes a "Before You Call" section with common issues and solutions, such as:

  • Unit not operating: Check power plug, circuit breaker, bucket installation, bucket full indicator, and ensure the unit is turned on.
  • Dehumidifier runs too much: Check for open windows/doors, room size, blocked airflow, recent installation, or if the unit is in CONTINUOUS mode.
  • Room not dry enough: Adjust humidity setting, check for recent installation, blocked airflow, or if the ambient temperature is too low (below 41°F/5°C).
  • Frost on coils: Normal during initial operation; usually disappears within 60 minutes. May also occur if ambient temperature is too low.
  • Fan noise: Normal sound of air moving through the dehumidifier.

Warranty:

A one-year limited warranty covers functional repairs due to defects in materials or workmanship. After one year, the consumer is responsible for diagnostic, labor, and parts costs. Exclusions include products with altered serial numbers, rust, commercial use, damage to the finish, and repairs by unauthorized technicians.