S3 Turbo
www.froeling.com
7
The Lambdatronic controller controls the induced draught fan and offers the option of connecting a
storage tank loading pump and a heating pump. Flue gas and boiler temperature monitoring ensures
efcient combustion.
S3 Turbo with S-Tronic and H2 hygienic layered tank
S3 Turbo with Lambdatronic, layered tank and Unicell
NOTICE
National and regional
regulations requiring
the use of weather-
compensated controls
should be observed.
The Lambdatronic controllers allow for efcient energy management. Up to 4 storage tanks, up to 8
hot water tanks and up to 18 heating circuits can be integrated into the heating management system.
You also benet from the ability to integrate other means of energy production, such as solar panels.
Hot water
Balancing
valve
S3 Turbo with S-Tronic
H2 Hygienic layered tank
Cold water
S3 Turbo with Lambdatronic
Layered tank
Unicell NT-S
water heater
Room sensor
(optional)
External
sensor
Balancing
valve
WEATHER-COMPENSATED
EXTERNAL HEATING CIRCUIT
CONTROL
FE
pump assembly