176
Cause: Mains overvoltage: The mains
voltage has exceeded the upper
limit of the tolerance range (see
section "Technical data")
Remedy: Check the mains voltage
Cause: The earth current watchdog has
triggered the safety cut-out of the
power source.
Remedy: Switch off the power source, wait
for 10 seconds and then switch it
on again. If you have tried this
several times and the error keeps
recurring, contact After-Sales
Service.
Cause: Wire stick
Remedy: Correct wire short circuit
Cause: Ignition time-out function is ac-
tive: no current started flowing be-
fore the end of the time specified
in the set-up menu. The safety
cut-out of the power source has
been triggered.
Remedy: Press the torch trigger repeated-
ly; clean the workpiece surface; if
necessary, increase the time until
the safety cut-out is triggered in
the set-up menu: level 2
Cause: Wire end - the wire-end check op-
tion has detected that there is no
more welding wire available
Remedy: Insert new wirespool
Cause: Arc break
Remedy: Press the torch trigger repeated-
ly; clean the surface of the work-
piece
Cause: Secondary overvoltage: safety
cut-out has tripped.
Remedy: Contact After-Sales Service