EasyManua.ls Logo

Fronius TIME 5000 Digital - Page 138

Fronius TIME 5000 Digital
212 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Unit % (of permanently settable parameter AL.1)
Setting range 0 - 30
Factory setting 0
NOTE!
The maximum amount by which parameter AL.1 can be increased or decreased is
the value specified for AL.c.
JSL
Job Slope - defines the time between the job that is currently selected and the next job
Unit s
Setting range OFF or 0.1 - 9.9
Factory setting OFF
Job
t (s)
Job 1
Job 2
Job 1
JSL = OFF
Job 1
JSL = 0,1 - 9,9 s
JSL
Job 2
Job Slope
The value that has been set for Job Slope is stored along with the Job currently selected.
138