ASt
Anti-stick
Unit -
Setting range ON, OFF
Factory setting OFF
Uco
U (Voltage) cut-off - Welding voltage limitation:
Unit V
Setting range OFF or 5 - 95
Factory setting OFF
NOTE!
The arc length depends on the welding voltage.
To end the welding process, it is usually necessary to significantly lift the rod electrode
away from the workpiece. With the “Uco” parameter, the welding voltage can be limited
to a value that makes it possible to end the welding operation simply by slightly lifting the
rod electrode.
If the welding process is stopped unintentionally during the welding, increase the value
for the Uco parameter.
Notes on the use
of the FAC para-
meter
The following parameters in Setup menu level 2 are not reset to the factory setting when
the FAC parameter is used:
- PPU
- C-C
- Stc
- Arc
- S4t
- Gun
161
EN
Toowoomba Welding Supplies : tweld.com.au : Ph +61 7 4659 0044

Table of Contents

Other manuals for Fronius TIME 5000 Digital

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TIME 5000 Digital and is the answer not in the manual?

Fronius TIME 5000 Digital Specifications

General IconGeneral
Input Voltage230 V
Max. Input Current22 A
Output Voltage230 V
Max. Output Current22 A
Maximum Output Power5000 W
Operating Temperature-25°C to +60°C
Input Frequency50 Hz
Output Frequency50 Hz