EasyManua.ls Logo

Fronius WF 25i REEL R /SA/2R/G/W - Unit Installation; Fitting the Wire-Feed Unit

Fronius WF 25i REEL R /SA/2R/G/W
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fitting the wire-feed unit
Fitting the wire-
feed unit
WARNING!
An electric shock can be fatal.
If the power source is connected to the mains supply while the work described below is
being carried out, there is a high risk of very serious injury and damage. Only carry out
the work described below when:
the power source mains switch is in the "O" position
the power source is unplugged from the mains
all system components are disconnected from the mains
The unreeling wire-feed unit is designed exclusively to be fitted vertically on the following
mounts:
- WF Mounting WALL 4,100,846
- WF Mounting Drum 4,100,845
1
Following the fitting instructions, mount the unreeling wire-feed unit onto the wall
bracket or the wire drum mount
2
Use the optional QuickConnect to connect the wirefeeding hose to the unreeling
wire-feed unit
3
If available:
use the optional robot control to connect the unreeling wire-feed unit to the robot
control
4
Connect the mains cable to the unreeling wire-feed unit
25
EN

Table of Contents

Related product manuals