EasyManuals Logo

Fujitsu AB12 User Manual

Fujitsu AB12
199 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
Thermistor resistance values <Outdoor unit side>
1) Outdoor heat exchanger temperature thermistor
Pipe tempera-
ture ( C)
Resistance value
(k )
-50
384.8
-40
182.8
-30
92.3
-20
49.2
-10
27.5
-7.5
24.0
-5.0
20.9
-2.5
18.3
0
16.1
2.5
14.1
5.0
12.4
7.5
11.0
10
9.7
Pipe tempera-
ture ( C)
Resistance value
(k )
12.5
8.6
15.0
7.7
17.5
6.8
20
6.1
22.5
5.5
25.0
4.9
27.5
4.4
30
3.9
32.5
3.6
35
3.2
37.5
2.9
40
2.6
50
1.8
Pipe tempera-
ture ( C)
Resistance value
(k )
60
1.2
70
0.9
80
0.6
90
0.5
100
0.4
2) Discharge pipe temperature thermistor
Pipe tempera-
ture ( C)
Resistance value
(k )
-40
2183
-30
1076
-20
561
-10
307
0
176
5.0
135
10
105
12.5
92.4
15
81.8
17.5
72.6
20
64.5
22.5
57.5
25
51.3
Pipe tempera-
ture ( C)
Resistance value
(k )
27.5
45.8
30
41.1
32.5
36.9
35
33.1
37.5
29.8
40
26.9
50
18.1
60
12.5
70
8.8
80
6.3
90
4.6
100
3.4
120
2.0
Pipe tempera-
ture ( C)
Resistance value
(k )
140
1.2
161
0.8
180
0.5
3) Outdoor temperature thermistor
Pipe tempera-
ture ( C)
Resistance value
(k )
-50
859
-40
402
-30
200
-20
105
-10
58.2
-7.5
50.6
-5.0
44.0
-2.5
38.4
0
33.6
2.5
29.5
5.0
25.9
8.0
22.3
10
20.2
Pipe tempera-
ture ( C)
Resistance value
(k )
12.5
17.9
15
15.8
17.5
14.1
20
12.5
22.5
11.2
25
10.0
27.5
9.0
30
8.0
32.5
7.2
35
6.5
37.5
5.9
40
5.3
50
3.6
Pipe tempera-
ture ( C)
Resistance value
(k )
60
2.5
70
1.8
80
1.3
– 125

Table of Contents