En-13
73
Electricity meter
pulse setting 2 *3
Setting number (00xx)
73
00
Setting number (01xx) 0 1
······ ··· ···
Setting number (98xx) 9 8
Setting number (99xx) 9 9
Set the hundreds digit and thousands digit of the electricity meter pulse setting connected
to CN135.
90
(Forbidden) 9 0 0 0
(Factory default)
*1: Do not set this for outdoor units with Slave setting.
*2: When electricity meter No. is set to “000” and “201 to 299”, the pulses input to CN135
become ineffective. Available setting number is "001" to "200"
*3: When the electricity meter pulse setting is set to “0000”, the pulses input to CN135
become ineffective. Available setting number is "0001" to "9999"
(1) Turn on the power of the outdoor unit and enter standby mode.
• When system is normal
POWER/MODE lamp lights up. (ERROR
lamp is off.)
• When system is abnormal
Check the settings as there is an error in
the settings for outdoor unit address
(DIP switch SET 3-1, 2) or number of
connected slave units (DIP switch SET
3-3, 4).
POWER/MODE
lamp: ON
ERROR
lamp: OFF
SELECT button
ENTER
button
MODE/EXIT
button
POWER
LED105 LED104
ERROR
MODE
LED101
(GREEN)
MODE
/EXIT
SELECT ENTER
SW107
SW108 SW109
LED102
(RED)
7 segment
display:
turn off
POWER/MODE
lamp: ON
7 segment
display: “-”
display
ERROR lamp:
Blinking
POWER
LED105 LED104
ERROR
MODE
LED101
(GREEN)
MODE
/EXIT
SELECT ENTER
SW107 SW108 SW109
LED102
(RED)
(2) Setting method
Use the “MODE/EXIT”, “SELECT”, and “ENTER” buttons to confi gure settings according
to the procedures below.
(If no setting is made, the factory default setting will be displayed.)
: Press the “MODE/EXIT” button
: Press the “SELECT” button
: Press the “ENTER” button.
: Press the “ENTER” button for more than 3 seconds.
1: Function setting
7 segment LED display
(LED 105, LED 104)
(Flashing)
First 2 digits
Last 2 digits
(When [F3] to [F9] are displayed, continue to press the
“SELECT” button until [F2] is displayed.)
2: Setting the fi rst
2 digits
3: Setting the last 2 digits
Continue to press the “SELECT” button until the
desired number appears at the last 2 digits.
Every press of the
“SELECT” button will
change the setting
number for the fi rst 2
digits.
(Continue to press the “SELECT”
button until the desired number
appears at the last 2 digits.)
Setting is complete when the lamp lights up
Press “ENTER” button to return to “2: Setting the
fi rst 2 digits” (If there is no operation for 5 seconds
after the setting, the display will return to “2: Setting
the fi rst 2 digits”.)
Setting is complete when the lamp lights up
Press “ENTER” button to return to “2: Setting the
fi rst 2 digits” (If there is no operation for 5 seconds
after the setting, the display will return to “2: Setting
the fi rst 2 digits”.)
EXIT: Press the “MODE/EXIT” button to cancel the setting mode.
7.5. Address setting for signal amplifi ers
7.5.1 Address setting for signal amplifi ers
When using signal amplifi ers, the address for signal amplifi ers must be set.
The address for signal amplifi ers can be set automatically from 1 outdoor unit (master
unit) on the network.
Refer to “Fig. Wiring example for automatic address setting” (7.6.1 chapter) for the wiring
example.
(For manual setting of address, refer to the signal amplifi er installation manual.)
7.5.2 Automatic address setting for signal amplifi ers
When setting the address of the signal amplifi er, please use the factory setting. (See the
installation manual of the signal amplifi er)
• When the system is normal, nothing will be displayed on the 7 segment display.
• When ERROR is displayed, inspect the units.
Use the “MODE/EXIT”, “SELECT”, and “ENTER” buttons on the outdoor unit PC board to
confi gure settings according to the procedures below.
9380545163-02_IM.indb 139380545163-02_IM.indb 13 5/17/2018 14:56:215/17/2018 14:56:21