1-3. Error code table (Indoor unit and wired remote controller)
The operation, timer, and economy indicators operate according to the error contents.
For confirmation of the error contents, refer the flashing pattern as follows.
Error contents
Indoor unit display Wired
remote
controller
display
Operation [ ]
(Green)
Timer [ ]
(Orange)
Economy [ ]
(Green)
E: 11. Serial communication error (Serial
reverse transfer error) (Outdoor unit)
1 times 1 times Continuous 11
E: 11. Serial communication error (Serial
forward transfer error) (Indoor unit)
1 times 1 times Continuous 11
E: 12. Wired remote controller
communication error (Indoor unit)
1 times 2 times Continuous 12
E: 18. External communication error (Indoor
unit)
1 times 8 times Continuous 18
E: 22. Indoor unit capacity error (Indoor
unit)
2 times 2 times Continuous 22
E: 23. Combination error (Outdoor unit) 2 times 3 times Continuous 23
E: 26. Address setting error in wired remote
controller (Indoor unit)
2 times 6 times Continuous 26
E: 29. Connected unit number error (Indoor
unit)
2 times 9 times Continuous 29
E: 32. Indoor unit main PCB error (Indoor
unit)
3 times 2 times Continuous 32
E: 33. Indoor unit motor electricity
consumption detection error (Indoor unit)
3 times 3 times Continuous 33
E: 35. MANUAL AUTO button error (Indoor
unit)
3 times 5 times Continuous 35
E: 39. Indoor unit power supply error for fan
motor (Indoor unit)
3 times 9 times Continuous 39
E: 3A. Indoor unit communication circuit
(wired remote controller) error
3 times 10 times Continuous 3A
E: 41. Room temperature sensor error
(Indoor unit)
4 times 1 times Continuous 41
E: 42. Indoor unit heat exchanger sensor
error (Indoor unit)
4 times 2 times Continuous 42
E: 45. Refrigerant leakage sensor error
(Indoor unit)
4 times 5 times Continuous 45
E: 45. Refrigerant leakage sensor
deterioration (Indoor unit)
4 times 5 times Continuous 45
E: 51. Indoor unit fan motor error (Indoor
unit)
5 times 1 times Continuous 51
E: 53. Drain pump error (Indoor unit) 5 times 3 times Continuous 53
E: 57. Damper (Open/Close) detection limit
switch error
5 times 7 times Continuous 57
E: 57. Damper (Open/Close) simultaneous
detection limit switch error (Indoor unit)
5 times 7 times Continuous 57
E: 58. Intake grille error (Indoor unit) 5 times 8 times Continuous 58
E: 5U. Indoor unit error 5 times 15 times Continuous 5U
E: 62. Outdoor unit model information error
(Outdoor unit)
6 times 2 times Continuous 62
E: 64. Active filter voltage error (Outdoor
unit)
6 times 4 times Continuous 64
E: 65. IPM error (Outdoor unit) 6 times 5 times Continuous 65
E: 71. Discharge thermistor error (Outdoor
unit)
7 times 1 times Continuous 71
E: 72. Compressor thermistor error
(Outdoor unit)
7 times 2 times Continuous 72
1-3. Error code table (Indoor unit and wired remote controller) - (03-2) - 1. Error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Other manuals for Fujitsu AO G12KATA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AO G12KATA Series and is the answer not in the manual?

Fujitsu AO G12KATA Series Specifications

General IconGeneral
BrandFujitsu
ModelAO G12KATA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals