• When function setting is "Forced stop" mode
– In the case of "Edge" input:
Function
setting /
Rotary SW on
External Input and
Output PCB
External input Input signal Command
46-02 60-00 / 1
External Input and
Output PCB
CN313
Off → On Forced stop
On → Off Normal
On
Off
Forced stop
Normal
Operation
Stop
Remote controller
On On
Indoor unit
On
CN313
– In the case of "Pulse" input:
Function
setting /
Rotary SW on
External Input and
Output PCB
External input Input signal Command
46-02 60-00 / 1
External Input and
Output PCB
CN313 Pulse Forced stop
CN314 Pulse Normal
On
Off
Operation
Stop
Remote controller
On
Off
Forced stop
Normal
CN313
CN314
On On On
Indoorunit
NOTES:
• When the forced stop is triggered, indoor unit stops and Operation/Stop operation by the re-
mote controller is restricted.
• When forced stop function is used with forming a remote controller group, connect the same
equipment to each indoor unit within the group.
- 210 -
12-3. Wall mounted type (KGTB, 18-24KMTB, KETA, and KETA-B)
12. External input and output
4-5 UNIT
MULTI-SPLIT TYPE
4-5 UNIT
MULTI-SPLIT TYPE

Table of Contents

Other manuals for Fujitsu AO G12KATA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AO G12KATA Series and is the answer not in the manual?

Fujitsu AO G12KATA Series Specifications

General IconGeneral
BrandFujitsu
ModelAO G12KATA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals