- (02 - 16) -
OUTDOOR UNIT
AOU9-15RLFFH
OUTDOOR UNIT
AOU9-15RLFFH
SAFETY DEVICES10.
Protection form
Model
AOU9RLFFH AOU12RLFFH AOU15RLFFH
Circuit protection
Current fuse
(Near the terminal)
250V 20A
250V 25A
250V 5A
Current fuse
(Main printed circuit board)
250V 15A 250V 10A
250V 3.15A 250V 3.15A
Fan motor protection
Thermal protection
program
OFF: 212 ± 27 °F (100 ± 15 °C)
ON: 203 ± 18 °F (95 ± 10 °C)
Compressor protection
Thermal protection
program
(Discharge temp.)
OFF: 230 °F (110 °C)
ON: After 7 minutes