Page #48 background image
- (02 - 14) -
OUTDOOR UNIT
AOU9-15RLS2
OUTDOOR UNIT
AOU9-15RLS2
SAFETY DEVICES10.
Protection form
Model
AOU9RLS2 AOU12RLS2 AOU15RLS2
Circuit protection
Current fuse
(NEAR THE TERMINAL)
20A 250V
25A 250V
5A 250V
Current fuse
(MAIN PRINTED CIRCUIT
BOARD)
15A 250V 10A 250V
3.15A 250V 3.15A 250V
Fan motor protection
Thermal protection
program
OFF : 212±18 °F (100±10 °C)
ON : 2018 °F (95±10 °C)
Compressor protection
Thermal protection
program
(DISCHARGE TEMP.)
OFF : 230 °F (110 °C)
ON : After 7 minutes