1-4. Setting the Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed.
Select the appropriate custom code.
( Factory setting)
Setting DescriptionFunction Number Setting Value
A
B
C
D
44
00
01
02
03
1-5. Setting the External input control
"Operation / Stop" mode or "Forced stop" mode can be selected.
( Factory setting)
Setting DescriptionFunction Number Setting Value
Operation / Stop mode
(Setting prohibited)
Forced stop mode
46
00
01
02
1-6. Setting the Room temperature sensor switching (Aux.)
1-7. Setting the Indoor unit fan control for energy saving for cooling
To use the temperature sensor on the wired remote controller
Enables or disables the power saving function by controlling the indoor unit fan rotation
when the outdoor unit is stopped during cooling operation.
only, change the setting to "Wired remote controller" (01).
This function will only work if the function setting 42 is set at "Both" (01)
)
Setting DescriptionFunction Number Setting Value
Both
Wired remote controller
48
00
01
( Factory setting
03-02
)
Setting DescriptionFunction Number Setting Value
Both
48
00
01
( Factory setting
)
Setting DescriptionFunction Number Setting Value
Disable
Enable
49
00
01
( Factory setting
)
Setting DescriptionFunction Number Setting Value
4
00
01
( Factory setting
00 : When the outdoor unit is stopped,the indoor unit fan operates continuously following the setting on
the remote controller.
01 : When the outdoor unit is stopped,the indoor unit fan operates intermittently at a very low speed.