EasyManua.ls Logo

Fujitsu AOU18RLB - Outdoor Fan Control

Fujitsu AOU18RLB
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6. OUTDOOR FAN CONTROL
( Table 8 : Outdoor fan speed )
*
The outdoor fan speed mentioned above depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequency decreases, the outdoor fan speed also changes to the
lower speed.)
*
After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed
as Table 9 without relating to the compressor frequency.
( Table 9 : Outdoor fan speed after the defrost )
1. Outdoor Fan Motor
2. Fan Speed
AC Motor DC Motor
AOU18RLB
The Table 7 shows the type of the outdoor fan motor.
The control method is different between AC motor and DC motor.
( Table 7 : Type of motor )
Fan speed
Cooling Heating
AOU18RLB
AOU24RLB
Y
Z
Zone
Refer to Fig. 8
(rpm)
F
G
Y
Z
F
G
Dry
250/ 200
300
300
1050/ 870/ 720/ 530
1050/ 870/ 720/ 530
870/530/300
1100/ 1000/ 780/ 720/ 590/ 480 530
1100/ 1000/ 780/ 720/ 590/ 480 530
870/530/300
250/ 200
AOU24RLB
AOU18RLB
1100rpm
1100rpm
( Fig. 8 : Outside air temperature zone selection )
70°F
(21°C)
50°F
(10°C)
Outside air
temperature rises
Outside air
temperature drops
Z zone
Y zone
F zone
G zone
54°F
(12°C)
36°F
(2°C)
66°F
(19°C)
32°F
( 0°C)
01-06
AOU24RLB

Other manuals for Fujitsu AOU18RLB