2. HORIZONTAL LOUVER CONTROL
Each time the button is pressed, the air direction range will
change as follows:
Cooling / Dry mode
Heating mode
Fan mode
Use the air direction adjustments within the ranges shown above.
The horizontal airflow direction is set automatically on
after initialization.
(Function Range)
(Fig.9 : Air Direction Range)
(Operation Range)
2-1. SWING OPERATION
When the swing signal is received from the remote controller, the horizontal louver starts to swing.
The range of swing depends on the set airflow direction.
When the indoor fan is either at S-Lo or Stop mode, the swinging operation is interrupted
and the louver stops at the memorized position.
01-09
( Stop mode means Operation stop.)
ABU18/ 24RULX
(
UNIVERSAL FLOOR/ CEILING TYPE)
ABU36RSLX
(
LARGE CEILING TYPE)
12 345
123
3
45
1
3
4
5
2
1
3
4
5
2
1
2
1
3
1
2
5
5
3
4
3
4
5
(Swinging Range)
Airflow direction set
Range of swing
to
to
to
to
1 5
to

Other manuals for Fujitsu AOU36RLX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOU36RLX and is the answer not in the manual?

Fujitsu AOU36RLX Specifications

General IconGeneral
BrandFujitsu
ModelAOU36RLX
CategoryAir Conditioner
LanguageEnglish

Related product manuals