INVERTER MULTI
AIR CONDITIONER
CONTENTS
SPECIFICATIONS . . . . . . . . . . . . . . . . . . .
1
DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . .
7
REFRIGERANT SYSTEM DIAGRAM . . .
14
ERROR DETECTION. . . . . . . . . . . . . . . .
37
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . .
15
INDOOR PCB CIRCUIT DIAGRAM . . . . .
20
OUTDOOR PCB CIRCUIT DIAGRAM . . .
23
PARTS (INDOOR UNIT) . . . . . . . . . . . . .
39
PARTS (OUTDOOR UNIT) . . . . . . . . . . .
44
ACCESSORIES. . . . . . . . . . . . . . . . . . . .
66
Indoor unitOutdoor unit
ASU7RLF
ASU9RLF
ASU12RLF
ASU18RLF
ASU24RLF
AUU9RLF
AUU12RLF
AUU18RLF
UTG-CCGF
ARU9RLF
ARU12RLF
ARU18RLF
ARU24RLF
AOU36RLXFZ

Other manuals for Fujitsu AOU36RLXFZ

Questions and Answers

  • A
    Amanda NicholsAug 13, 2025
    What to do if my Fujitsu AOU36RLXFZ remote is not working due to a communication error?
    • R
      Roy RamirezAug 13, 2025
      If you're experiencing a Wired Remote Controller Communication Error with your Fujitsu Air Conditioner, check the voltage. If it's DC12V, the remote control has failed and should be replaced. If it's DC 0V, the Controller PCB has failed and should be replaced after rechecking the remote control.
  • K
    Karen WelchAug 17, 2025
    What to do if my Fujitsu Air Conditioner has a drainage error?
    • S
      Stephen BrownAug 17, 2025
      If your Fujitsu Air Conditioner is experiencing drainage issues, start by inspecting the float switch for proper operation using a meter to check its on/off switching. If the float switch is defective, replace it. Also, examine the drain hose for any clogs and clear them if necessary. If these steps don't resolve the issue, consider replacing the controller PCB.
  • E
    Elizabeth GreeneAug 20, 2025
    How to fix a Fujitsu Air Conditioner indoor unit fan motor error?
    • K
      Kendra ChandlerAug 21, 2025
      If you're encountering an indoor unit fan motor error with your Fujitsu Air Conditioner, check first the fan and bearing. If either is damaged, replace them. If the motor itself is faulty, replace the indoor unit fan motor. If these steps do not resolve the issue, replace the controller PCB.
  • L
    leslie38Aug 25, 2025
    What to do if my Fujitsu Air Conditioner shows an indoor room thermistor error?
    • R
      Richard PetersonAug 25, 2025
      If your Fujitsu Air Conditioner displays an indoor room thermistor error, begin by checking the connector to ensure it is securely attached and properly connected, and verify that the thermistor cable is not open. If the thermistor is either open or shorted, replace it and then reset the power.
  • C
    costamichaelAug 28, 2025
    How to troubleshoot an Indoor Unit Model Information Error on my Fujitsu AOU36RLXFZ Air Conditioner?
    • A
      Ashley HolmesAug 28, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Model Information Error, check for external causes such as noise and ensure the ground connection is properly connected. Also, inspect all connectors for looseness or incorrect wiring, and check the PCB for any shorts or corrosion. If the problem persists, consider replacing the Controller PCB.
  • T
    Timothy NicholsSep 1, 2025
    What does an Indoor Unit Capacity Error mean on my Fujitsu AOU36RLXFZ Air Conditioner?
    • L
      lisa71Sep 1, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Capacity Error, first verify the total capacity of the connected indoor units. If an abnormal condition is found, correct it by referring to the Installation Manual or Design & Technical Manual. If the problem persists, replace the Main PCB of the Outdoor unit.
  • T
    Terri SwansonSep 5, 2025
    How to fix a Serial Communication Error (Serial Reverse Transfer Error) on a Fujitsu AOU36RLXFZ Air Conditioner?
    • M
      murphystevenSep 5, 2025
      If your Fujitsu Air Conditioner displays a Serial Communication Error (Serial Reverse Transfer Error), check all connection lines between the indoor and outdoor units for any looseness or disconnections, referring to the Installation Manual or Data & Technical Manual for correction. Also, check the voltage of the power supply, ensuring it appears at the outdoor unit terminal L1 - L2 within the range of AC187V - 253V. Check that the indicated value swings between AC90V and AC270V at outdoor unit terminal 1 - 3. If the outdoor fan motor, active filter module, or IPM is abnormal, replace the corresponding part. If all parts are normal, replace the Main PCB.
  • A
    andrea84Sep 8, 2025
    How to resolve a Damper (Open/Close) simultaneous detection Limit switch error on a Fujitsu Air Conditioner?
    • D
      David FosterSep 9, 2025
      If your Fujitsu Air Conditioner displays a Damper(Open/Close) simultaneous detection Limit switch error, replace the limit switch if it is defective. If the problem persists, replace the Controller PCB.

Summary

Specifications

Outdoor Unit Specifications

Electrical, refrigerant, and measurement details for the outdoor unit.

Indoor Unit Compact Wall Mounted Specifications

Electrical, fan, airflow, noise, and measurement specs for compact wall units.

Indoor Unit Wall Mounted Specifications

Electrical, fan, airflow, noise, and measurement specs for wall mounted units.

Indoor Unit Compact Cassette Specifications

Electrical, fan, airflow, noise, and measurement specs for cassette units.

Indoor Unit Slim Duct Specifications

Electrical, fan, airflow, and measurement specs for slim duct units.

Indoor Unit Slim Duct Specifications (Continued)

Electrical, fan, airflow, and measurement specs for larger slim duct units.

Dimensions

Outdoor Unit Dimensions

Detailed diagrams and measurements for the outdoor unit.

Indoor Unit Compact Wall Mounted Dimensions

Detailed diagrams and measurements for compact wall mounted indoor units.

Indoor Unit Wall Mounted Dimensions

Detailed diagrams and measurements for wall mounted indoor units.

Indoor Unit Compact Cassette Dimensions

Detailed diagrams and measurements for compact cassette indoor units.

Indoor Unit Slim Duct Dimensions

Detailed diagrams and measurements for slim duct indoor units.

Indoor Unit Slim Duct Dimensions (Continued)

Further detailed diagrams and measurements for slim duct indoor units.

Indoor Unit Slim Duct Dimensions (Final)

Final detailed diagrams and measurements for slim duct indoor units.

Refrigerant System Diagram

Circuit Diagrams

Outdoor Unit Circuit Diagram

Wiring diagram for the outdoor unit's electrical connections.

Indoor Unit Circuit Diagrams

Wiring diagrams for various indoor unit types.

Controller PCB Assembly (Main PCB)

Detailed schematic of the main controller PCB.

Outdoor Unit Power Supply PCB Assembly

Schematic for the outdoor unit's power supply PCB.

Indoor Unit PCB Diagrams

Circuit diagrams for various indoor unit PCBs and related components.

Error Detection

Table detailing error codes and LED indicators for troubleshooting.

Accessories

Outdoor Unit Accessories

List of optional accessories for the outdoor unit.

Indoor Unit Accessories (Compact Wall Mounted & Wall Mounted)

Optional accessories for compact wall and standard wall mounted indoor units.

Indoor Unit Accessories (Compact Cassette)

Optional accessories for compact cassette indoor units and decoration panels.

Indoor Unit Accessories (Slim Duct)

Optional accessories for slim duct indoor units.

Fujitsu AOU36RLXFZ Specifications

General IconGeneral
BrandFujitsu
ModelAOU36RLXFZ
CategoryAir Conditioner
LanguageEnglish

Related product manuals